AD 84-13-01
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | M7 Aerospace LLC | SA226-TC | FAIRCHILD (SWEARINGEN) Models SA226-TC, SA227-AT and SA227-TT Airplanes |
| aircraft | M7 Aerospace LLC | SA227-AC (C-26A) | FAIRCHILD (SWEARINGEN) Models SA226-TC, SA227-AT and SA227-TT Airplanes |
| aircraft | M7 Aerospace LLC | SA227-AT | FAIRCHILD (SWEARINGEN) Models SA226-TC, SA227-AT and SA227-TT Airplanes |
| aircraft | M7 Aerospace LLC | SA227-TT | FAIRCHILD (SWEARINGEN) Models SA226-TC, SA227-AT and SA227-TT Airplanes |
Unsafe Condition
Cockpit fires can occur due to flammable fluid leaks, oxygen line leaks or inadequate clearance from moving parts, and electrical wire contact with oxygen tubing or hydraulic lines.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Within 50 hours time-in-service after the effective date, modify and inspect the generator control J-box and wire terminations per SBs 24-003 or 24-021. Inspect flammable fluid drains, check oxygen lines for leaks and clearance, and inspect electrical wires for clearance from oxygen tubing. Adjust inspection intervals up to 10% for maintenance coordination. Equivalent compliance may be approved.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
within 50 hours time-in-service after the effective date of this AD
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Fairchild (Swearingen) Models SA226-TC (S/N 398 and up), SA227-AC, SA227-AT, and SA227-TT (all serial numbers) airplanes
AI-generated summary from the source AD text. Verify against the official source before acting.
Source: Official FAA Source ↗
Retrieved: Apr 8, 2026
Rights: U.S. Government Public Domain