AD 82-22-03
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Alexandria Aircraft, LLC | EAGLE DW-1 | Airworthiness Directives; Eagle Model DW-1 Airplanes |
Unsafe Condition
Loss of elevator control due to failure of the aft elevator push tube.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Replace the existing Aft Elevator Push Tube Assembly (P/N 162000-16) with a new P/N 162000-29 in accordance with Eagle Aircraft Co. Service Letter No. 82-6. Compliance must be within 25 hours after the effective date for airplanes with 400+ hours time-in-service or before 425 hours time-in-service for those with less than 400 hours, and every 400 hours thereafter.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Within 25 hours after the effective date of this AD on airplanes having 400 or more hours time-in-service or prior to the accumulation of 425 hours time-in-service on airplanes with less than 400 hours time-in-service and each 400 hours time-in-service thereafter
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Alexandria Aircraft, LLC Model EAGLE DW-1 airplanes certificated in any category.
AI-generated summary from the source AD text. Verify against the official source before acting.
Source: Official FAA Source ↗
Retrieved: Apr 8, 2026
Rights: U.S. Government Public Domain