AD 81-19-07

final rule

BOEING Model 727 Airplanes

AD Number
81-19-07
Status
final_rule
Effective Date
Product Category
aircraft
Docket
Unknown
FR Citation
This information is not available.

Applicability

TypeManufacturerModelDetails
aircraft The Boeing Company 727-100 Series BOEING Model 727 Airplanes
aircraft The Boeing Company 727-100C Series BOEING Model 727 Airplanes
aircraft The Boeing Company 727-200 Series BOEING Model 727 Airplanes
aircraft The Boeing Company 727-200F Series BOEING Model 727 Airplanes
aircraft The Boeing Company 727 Series BOEING Model 727 Airplanes
aircraft The Boeing Company 727C Series BOEING Model 727 Airplanes

Unsafe Condition

Failure of the Air Flow Multiplier could result in loss of pressurization or structural damage to the airplane.

AI-generated summary from the source AD text. Verify against the official source before acting.

Required Actions

Within 300 hours time-in-service after the effective date, begin performing repetitive inspections of the Air Flow Multiplier per Boeing Alert Service Bulletin 727-21A95, repeated every 1000 hours time-in-service. Alternatively, accomplish AiResearch Service Bulletin 21-2291 modification or approved equivalent actions.

AI-generated summary from the source AD text. Verify against the official source before acting.

Compliance Time

Within 300 hours time-in-service after the effective date of this AD

AI-generated summary from the source AD text. Verify against the official source before acting.

Affected Aircraft

Boeing Model 727 airplanes with Air Flow Multiplier installed through line number 1264 where AiResearch Service Bulletin 21-2291 has not been incorporated

AI-generated summary from the source AD text. Verify against the official source before acting.

Federal Register Abstract

Air Flow Multiplier

Applicability Source Text

Show captured applicability text from the source AD
AD Final Rules - DRS_81-19-07.html
Copy URL
Print/Save as PDF
Document Versions
 Feedback
Details
AD Number:
81-19-07
Document Type:
AD Final Rules
Docket Number:
Unknown
Subject Heading:
BOEING Model 727 Airplanes
Subject:
Air Flow Multiplier
Status:
Current
Citation:
This information is not available.
Citation Publish Date:
Effective Date:
09/20/1981
Make:
The Boeing Company
Model:
727-100 Series | 727-100C Series | 727-200 Series | 727-200F Series | 727 Series | 727C Series
Product Type:
Aircraft
Product Subtype:
Large Airplane
Affected AD:
Superseded AD:
Affected By:
Superseded By:
Service/Office:
Office of Primary Responsibility:
CFR Part Reference:
Part 39
Comments:
AIRWORTHINESS DIRECTIVES FINAL RULES: 81-19-07
CITATION:   This information is not available.

PAGE NUMBER:  

DOCKET NUMBER:   Unknown

AMENDMENT:   39-4212

AD NUMBER:   81-19-07

SUBJECT HEADING:   BOEING Model 727 Airplanes

ACTION:  

SUMMARY:  

DATES:   Effective September 20, 1981.

ADDRESSES:  

FOR FURTHER INFORMATION CONTACT:  

SUPPLEMENTARY INFORMATION:  

REGULATORY TEXT:  
81-19-07 BOEING: Amendment 39-4212. Applies to Boeing Model 727 airplanes certificated in all categories with the Air Flow Multiplier installed, through line number 1264, on which AiResearch Service Bulletin 21-2291 has not been incorporated.

Within 300 hours time-in-service after the effective date of this AD, accomplish one of the following, unless already accomplished:

A. Begin performing the repetitive inspections of the Air Flow Multiplier in accordance with Boeing Alert Service Bulletin 727-21A95, dated May 29, 1981. This inspection must be repeated at intervals not to exceed 1000 hours time-in-service. Step B or C below may be used for terminating action for these repetitive inspections.

B. Accomplish the modification to the air flow multiplier in accordance with AiResearch Service Bulletin 21-2291.

C. Alternative inspections, repairs, or other action which provide an equivalent level of safety may be used when approved by the Chief, Seattle Area Aircraft Certification Office, FAA Northwest Region.

The manufacturer's specifications and procedures identified and described in this directive are incorporated herein and made a part hereof pursuant to 5 U.S.C. 552(a)(1).

All persons affected by this directive who have not already received the above specified alert service bulletin from the manufacturer may obtain copies upon request to Boeing Commercial Airplane Company, P.O. Box 3707, Seattle, Washington 98124, or it may be examined at FAA Northwest Region, 9010 East Marginal Way South, Seattle, Washington 98108.

This amendment becomes effective September 20, 1981.

FOOTER:

Document Text

Show stored source text (verify against official source)
AD Final Rules - DRS_81-19-07.html
Copy URL
Print/Save as PDF
Document Versions
 Feedback
Details
AD Number:
81-19-07
Document Type:
AD Final Rules
Docket Number:
Unknown
Subject Heading:
BOEING Model 727 Airplanes
Subject:
Air Flow Multiplier
Status:
Current
Citation:
This information is not available.
Citation Publish Date:
Effective Date:
09/20/1981
Make:
The Boeing Company
Model:
727-100 Series | 727-100C Series | 727-200 Series | 727-200F Series | 727 Series | 727C Series
Product Type:
Aircraft
Product Subtype:
Large Airplane
Affected AD:
Superseded AD:
Affected By:
Superseded By:
Service/Office:
Office of Primary Responsibility:
CFR Part Reference:
Part 39
Comments:
AIRWORTHINESS DIRECTIVES FINAL RULES: 81-19-07
CITATION:   This information is not available.

PAGE NUMBER:  

DOCKET NUMBER:   Unknown

AMENDMENT:   39-4212

AD NUMBER:   81-19-07

SUBJECT HEADING:   BOEING Model 727 Airplanes

ACTION:  

SUMMARY:  

DATES:   Effective September 20, 1981.

ADDRESSES:  

FOR FURTHER INFORMATION CONTACT:  

SUPPLEMENTARY INFORMATION:  

REGULATORY TEXT:  
81-19-07 BOEING: Amendment 39-4212. Applies to Boeing Model 727 airplanes certificated in all categories with the Air Flow Multiplier installed, through line number 1264, on which AiResearch Service Bulletin 21-2291 has not been incorporated.

Within 300 hours time-in-service after the effective date of this AD, accomplish one of the following, unless already accomplished:

A. Begin performing the repetitive inspections of the Air Flow Multiplier in accordance with Boeing Alert Service Bulletin 727-21A95, dated May 29, 1981. This inspection must be repeated at intervals not to exceed 1000 hours time-in-service. Step B or C below may be used for terminating action for these repetitive inspections.

B. Accomplish the modification to the air flow multiplier in accordance with AiResearch Service Bulletin 21-2291.

C. Alternative inspections, repairs, or other action which provide an equivalent level of safety may be used when approved by the Chief, Seattle Area Aircraft Certification Office, FAA Northwest Region.

The manufacturer's specifications and procedures identified and described in this directive are incorporated herein and made a part hereof pursuant to 5 U.S.C. 552(a)(1).

All persons affected by this directive who have not already received the above specified alert service bulletin from the manufacturer may obtain copies upon request to Boeing Commercial Airplane Company, P.O. Box 3707, Seattle, Washington 98124, or it may be examined at FAA Northwest Region, 9010 East Marginal Way South, Seattle, Washington 98108.

This amendment becomes effective September 20, 1981.

FOOTER:

Source: Official FAA Source ↗

Retrieved: Apr 8, 2026

Rights: U.S. Government Public Domain

This site is not affiliated with or endorsed by the FAA. Always verify with official sources.