AD 78-14-02

final rule

Airworthiness Directives; AVIONS MARCEL DASSAULT-BREGUET AVIATION (AMD-BA) Model Falcon 10 Airplanes

AD Number
78-14-02
Status
final_rule
Effective Date
Product Category
aircraft
Docket
Unknown
FR Citation
This information is not available.

Applicability

TypeManufacturerModelDetails
aircraft Dassault Aviation Falcon 10 Airworthiness Directives; AVIONS MARCEL DASSAULT-BREGUET AVIATION (AMD-BA) Model Falcon 10 Airplanes

Unsafe Condition

Jamming of the oxygen pressure reducing valve due to water condensation freezing in the valve expansion chamber.

AI-generated summary from the source AD text. Verify against the official source before acting.

Required Actions

Modify the oxygen pressure reducing valve installation in accordance with AMD-BA Service Bulletin F10-0135 dated February 11, 1977, including Revision 2, dated January 4, 1978, or an approved modification.

AI-generated summary from the source AD text. Verify against the official source before acting.

Compliance Time

within the next 150 hours time in service after the effective date of this AD

AI-generated summary from the source AD text. Verify against the official source before acting.

Affected Aircraft

Falcon 10 airplanes serial numbers 1 through 108, except serial numbers 93, 101 and 103

AI-generated summary from the source AD text. Verify against the official source before acting.

Federal Register Abstract

Oxygen Pressure

Applicability Source Text

Show captured applicability text from the source AD
AD Final Rules - DRS_78-14-02.html
Copy URL
Print/Save as PDF
Document Versions
 Feedback
Details
AD Number:
78-14-02
Document Type:
AD Final Rules
Docket Number:
Unknown
Subject Heading:
Airworthiness Directives; AVIONS MARCEL DASSAULT-BREGUET AVIATION (AMD-BA) Model Falcon 10 Airplanes
Subject:
Oxygen Pressure
Status:
Current
Citation:
This information is not available.
Citation Publish Date:
Effective Date:
07/11/1978
Make:
Dassault Aviation
Model:
Falcon 10
Product Type:
Aircraft
Product Subtype:
Large Airplane
Affected AD:
Superseded AD:
Affected By:
Superseded By:
Service/Office:
Office of Primary Responsibility:
CFR Part Reference:
Part 39
Comments:
AIRWORTHINESS DIRECTIVES FINAL RULES: 78-14-02
CITATION:   This information is not available.

PAGE NUMBER:  

DOCKET NUMBER:   Unknown

AMENDMENT:   39-3256

AD NUMBER:   78-14-02

SUBJECT HEADING:   Airworthiness Directives; AVIONS MARCEL DASSAULT-BREGUET AVIATION (AMD-BA) Model Falcon 10 Airplanes

ACTION:  

SUMMARY:  

DATES:   Effective July 11, 1978.

ADDRESSES:  

FOR FURTHER INFORMATION CONTACT:  

SUPPLEMENTARY INFORMATION:  

REGULATORY TEXT:  
78-14-02 AVIONS MARCEL DASSAULT-BREGUET AVIATION (AMD-BA): Amendment 39-3256. Applies to Falcon 10 airplanes serial numbers 1 through 108, except serial numbers 93, 101 and 103, certificated in all categories.

Compliance is required within the next 150 hours time in service after the effective date of this AD, unless already accomplished.

To reduce the possibility of jamming of the oxygen pressure reducing valve due to water condensation freezing in the valve expansion chamber, modify the oxygen pressure reducing valve installation in accordance with AMD-BA Service Bulletin F10-0135 dated February 11, 1977, including Revision 2, dated January 4, 1978, or a modification approved by the Chief, Aircraft Certification Staff, FAA, Europe, Africa, and Middle East Region.

NOTE: The oxygen pressure reducing valve is located in the righthand side of the nose landing gear wheel well.

This amendment becomes effective July 11, 1978.

FOOTER:

Document Text

Show stored source text (verify against official source)
AD Final Rules - DRS_78-14-02.html
Copy URL
Print/Save as PDF
Document Versions
 Feedback
Details
AD Number:
78-14-02
Document Type:
AD Final Rules
Docket Number:
Unknown
Subject Heading:
Airworthiness Directives; AVIONS MARCEL DASSAULT-BREGUET AVIATION (AMD-BA) Model Falcon 10 Airplanes
Subject:
Oxygen Pressure
Status:
Current
Citation:
This information is not available.
Citation Publish Date:
Effective Date:
07/11/1978
Make:
Dassault Aviation
Model:
Falcon 10
Product Type:
Aircraft
Product Subtype:
Large Airplane
Affected AD:
Superseded AD:
Affected By:
Superseded By:
Service/Office:
Office of Primary Responsibility:
CFR Part Reference:
Part 39
Comments:
AIRWORTHINESS DIRECTIVES FINAL RULES: 78-14-02
CITATION:   This information is not available.

PAGE NUMBER:  

DOCKET NUMBER:   Unknown

AMENDMENT:   39-3256

AD NUMBER:   78-14-02

SUBJECT HEADING:   Airworthiness Directives; AVIONS MARCEL DASSAULT-BREGUET AVIATION (AMD-BA) Model Falcon 10 Airplanes

ACTION:  

SUMMARY:  

DATES:   Effective July 11, 1978.

ADDRESSES:  

FOR FURTHER INFORMATION CONTACT:  

SUPPLEMENTARY INFORMATION:  

REGULATORY TEXT:  
78-14-02 AVIONS MARCEL DASSAULT-BREGUET AVIATION (AMD-BA): Amendment 39-3256. Applies to Falcon 10 airplanes serial numbers 1 through 108, except serial numbers 93, 101 and 103, certificated in all categories.

Compliance is required within the next 150 hours time in service after the effective date of this AD, unless already accomplished.

To reduce the possibility of jamming of the oxygen pressure reducing valve due to water condensation freezing in the valve expansion chamber, modify the oxygen pressure reducing valve installation in accordance with AMD-BA Service Bulletin F10-0135 dated February 11, 1977, including Revision 2, dated January 4, 1978, or a modification approved by the Chief, Aircraft Certification Staff, FAA, Europe, Africa, and Middle East Region.

NOTE: The oxygen pressure reducing valve is located in the righthand side of the nose landing gear wheel well.

This amendment becomes effective July 11, 1978.

FOOTER:

Source: Official FAA Source ↗

Retrieved: Apr 8, 2026

Rights: U.S. Government Public Domain

This site is not affiliated with or endorsed by the FAA. Always verify with official sources.