AD 77-07-02

final rule
Data completeness: 70%

Airworthiness Directives; AVIONS MARCEL DASSAULT (AMD)Model Fan Jet Falcon Airplanes

AD Number
77-07-02
Status
final_rule
Effective Date
Product Category
aircraft
Docket
Unknown
FR Citation
This information is not available.

Applicability

TypeManufacturerModelDetails
aircraft Dassault Aviation Fan Jet Falcon Airworthiness Directives; AVIONS MARCEL DASSAULT (AMD)Model Fan Jet Falcon Airplanes

Unsafe Condition

Possible horizontal stabilizer trim runaway due to positive voltage wire connected to normally-closed contacts of pilot's and copilot's horizontal stabilizer trim control switches.

AI-generated summary from the source AD text. Verify against the official source before acting.

Required Actions

Remove the positive voltage wire from the normally-closed contacts of the pilot's and copilot's horizontal stabilizer trim control switches in accordance with AMD Service Bulletin No. 568, Revision 1 dated October 25, 1976, or an FAA-approved equivalent.

AI-generated summary from the source AD text. Verify against the official source before acting.

Compliance Time

within the next 300 hours time in service after the effective date of this AD

AI-generated summary from the source AD text. Verify against the official source before acting.

Affected Aircraft

All Fan Jet Falcon airplanes, all series, certificated in all categories, not incorporating AMD Modification No. 2092.