Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Dassault Aviation | Fan Jet Falcon | Airworthiness Directives; AVIONS MARCEL DASSAULT (AMD)Model Fan Jet Falcon Airplanes |
Unsafe Condition
Possible horizontal stabilizer trim runaway due to positive voltage wire connected to normally-closed contacts of pilot's and copilot's horizontal stabilizer trim control switches.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Remove the positive voltage wire from the normally-closed contacts of the pilot's and copilot's horizontal stabilizer trim control switches in accordance with AMD Service Bulletin No. 568, Revision 1 dated October 25, 1976, or an FAA-approved equivalent.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
within the next 300 hours time in service after the effective date of this AD
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
All Fan Jet Falcon airplanes, all series, certificated in all categories, not incorporating AMD Modification No. 2092.
AI-generated summary from the source AD text. Verify against the official source before acting.
Source: Official FAA Source ↗
Retrieved: Apr 8, 2026
Rights: U.S. Government Public Domain