AD 76-19-05

final rule

Airworthiness Directives; AVIONS MARCEL DASSAULT (AMD) Model Fan Jet Falcon Airplanes

AD Number
76-19-05
Status
final_rule
Effective Date
Product Category
aircraft
Docket
Unknown
FR Citation
This information is not available.

Applicability

TypeManufacturerModelDetails
aircraft Dassault Aviation Fan Jet Falcon Airworthiness Directives; AVIONS MARCEL DASSAULT (AMD) Model Fan Jet Falcon Airplanes

Unsafe Condition

The emergency fuel shut-off valves may fail to shut down the engines within the required 15 seconds after actuation due to improper assembly or adjustment of the fuel shut-off control.

AI-generated summary from the source AD text. Verify against the official source before acting.

Required Actions

Inspect the fuel shut-off control within 20 hours time in service after the effective date to ensure flame-out occurs within 15 seconds. Readjust the control if necessary. Inspect and repair the fuel shut-off valves (Zenith P/N B99-26203 and B99-26204) within 150 hours time in service or 60 days after the effective date, whichever occurs later.

AI-generated summary from the source AD text. Verify against the official source before acting.

Compliance Time

Within the next 20 hours time in service after the effective date of this AD for the fuel shut-off control inspection, and within the next 150 hours time in service or 60 days after the effective date for the fuel shut-off valves inspection.

AI-generated summary from the source AD text. Verify against the official source before acting.

Affected Aircraft

AVIONS MARCEL DASSAULT (AMD) Model Fan Jet Falcon airplanes, all Series, certificated in all categories.

AI-generated summary from the source AD text. Verify against the official source before acting.

Federal Register Abstract

Engine Emergency Fuel Shut-Off Valves

Applicability Source Text

Show captured applicability text from the source AD
AD Final Rules - DRS_76-19-05.html
Copy URL
Print/Save as PDF
Document Versions
 Feedback
Details
AD Number:
76-19-05
Document Type:
AD Final Rules
Docket Number:
Unknown
Subject Heading:
Airworthiness Directives; AVIONS MARCEL DASSAULT (AMD) Model Fan Jet Falcon Airplanes
Subject:
Engine Emergency Fuel Shut-Off Valves
Status:
Current
Citation:
This information is not available.
Citation Publish Date:
Effective Date:
10/07/1976
Make:
Dassault Aviation
Model:
Fan Jet Falcon
Product Type:
Aircraft
Product Subtype:
Large Airplane
Affected AD:
Superseded AD:
Affected By:
Superseded By:
Service/Office:
Office of Primary Responsibility:
CFR Part Reference:
Part 39
Comments:
AIRWORTHINESS DIRECTIVES FINAL RULES: 76-19-05
CITATION:   This information is not available.

PAGE NUMBER:  

DOCKET NUMBER:   Unknown

AMENDMENT:   39-2730

AD NUMBER:   76-19-05

SUBJECT HEADING:   Airworthiness Directives; AVIONS MARCEL DASSAULT (AMD) Model Fan Jet Falcon Airplanes

ACTION:  

SUMMARY:  

DATES:   DATE: Effective October 7, 1976.

ADDRESSES:  

FOR FURTHER INFORMATION CONTACT:  

SUPPLEMENTARY INFORMATION:  

REGULATORY TEXT:  
76-19-05 AVIONS MARCEL DASSAULT (AMD): Amendment 39-2730. Applies to all Model Fan Jet Falcon airplanes, all Series, certificated in all categories.

Compliance is required as indicated, unless already accomplished.

To prevent the possible inability of the emergency fuel shut-off valves to shut down the engines, accomplish the following:

(a) Within the next 20 hours time in service after the effective date of this AD, unless already accomplished, inspect the fuel shut-off control in accordance with AMD Service Bulletin No. 551, dated March 3, 1976, or FAA-approved equivalent, for each engine to determine the time for the engine to flame-out after actuation of the emergency fuel shut-off control with the engine operating initially at ground idle rpm. If flame-out time is found to exceed 15 seconds, prior to further flight, except that the airplane may be flown in accordance with FARs 21.197 and 21.199 to a base where the repair can be performed, readjust the emergency fuel shut-off control in accordance with Fan Jet Falcon Maintenance Manual Chapter 76-20-2, pages 501 through 503, or an FAA-approved equivalent.

(b) Within the next 150 hours time in service or 60 days after the effective date of this AD, whichever occurs later, unless already accomplished, inspect for proper assembly and repair, as necessary, the fuel shut-off valves, Zenith P/N B99-26203 and B99-26204, in accordance with AMD Service Bulletin No. 550, dated March 3, 1976, or an FAA-approved equivalent.

This amendment becomes effective October 7, 1976.

FOOTER:

Document Text

Show stored source text (verify against official source)
AD Final Rules - DRS_76-19-05.html
Copy URL
Print/Save as PDF
Document Versions
 Feedback
Details
AD Number:
76-19-05
Document Type:
AD Final Rules
Docket Number:
Unknown
Subject Heading:
Airworthiness Directives; AVIONS MARCEL DASSAULT (AMD) Model Fan Jet Falcon Airplanes
Subject:
Engine Emergency Fuel Shut-Off Valves
Status:
Current
Citation:
This information is not available.
Citation Publish Date:
Effective Date:
10/07/1976
Make:
Dassault Aviation
Model:
Fan Jet Falcon
Product Type:
Aircraft
Product Subtype:
Large Airplane
Affected AD:
Superseded AD:
Affected By:
Superseded By:
Service/Office:
Office of Primary Responsibility:
CFR Part Reference:
Part 39
Comments:
AIRWORTHINESS DIRECTIVES FINAL RULES: 76-19-05
CITATION:   This information is not available.

PAGE NUMBER:  

DOCKET NUMBER:   Unknown

AMENDMENT:   39-2730

AD NUMBER:   76-19-05

SUBJECT HEADING:   Airworthiness Directives; AVIONS MARCEL DASSAULT (AMD) Model Fan Jet Falcon Airplanes

ACTION:  

SUMMARY:  

DATES:   DATE: Effective October 7, 1976.

ADDRESSES:  

FOR FURTHER INFORMATION CONTACT:  

SUPPLEMENTARY INFORMATION:  

REGULATORY TEXT:  
76-19-05 AVIONS MARCEL DASSAULT (AMD): Amendment 39-2730. Applies to all Model Fan Jet Falcon airplanes, all Series, certificated in all categories.

Compliance is required as indicated, unless already accomplished.

To prevent the possible inability of the emergency fuel shut-off valves to shut down the engines, accomplish the following:

(a) Within the next 20 hours time in service after the effective date of this AD, unless already accomplished, inspect the fuel shut-off control in accordance with AMD Service Bulletin No. 551, dated March 3, 1976, or FAA-approved equivalent, for each engine to determine the time for the engine to flame-out after actuation of the emergency fuel shut-off control with the engine operating initially at ground idle rpm. If flame-out time is found to exceed 15 seconds, prior to further flight, except that the airplane may be flown in accordance with FARs 21.197 and 21.199 to a base where the repair can be performed, readjust the emergency fuel shut-off control in accordance with Fan Jet Falcon Maintenance Manual Chapter 76-20-2, pages 501 through 503, or an FAA-approved equivalent.

(b) Within the next 150 hours time in service or 60 days after the effective date of this AD, whichever occurs later, unless already accomplished, inspect for proper assembly and repair, as necessary, the fuel shut-off valves, Zenith P/N B99-26203 and B99-26204, in accordance with AMD Service Bulletin No. 550, dated March 3, 1976, or an FAA-approved equivalent.

This amendment becomes effective October 7, 1976.