AD 76-19-05
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Dassault Aviation | Fan Jet Falcon | Airworthiness Directives; AVIONS MARCEL DASSAULT (AMD) Model Fan Jet Falcon Airplanes |
Unsafe Condition
The emergency fuel shut-off valves may fail to shut down the engines within the required 15 seconds after actuation due to improper assembly or adjustment of the fuel shut-off control.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Inspect the fuel shut-off control within 20 hours time in service after the effective date to ensure flame-out occurs within 15 seconds. Readjust the control if necessary. Inspect and repair the fuel shut-off valves (Zenith P/N B99-26203 and B99-26204) within 150 hours time in service or 60 days after the effective date, whichever occurs later.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Within the next 20 hours time in service after the effective date of this AD for the fuel shut-off control inspection, and within the next 150 hours time in service or 60 days after the effective date for the fuel shut-off valves inspection.
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
AVIONS MARCEL DASSAULT (AMD) Model Fan Jet Falcon airplanes, all Series, certificated in all categories.
AI-generated summary from the source AD text. Verify against the official source before acting.