AD 74-22-03

final rule
Data completeness: 70%

Airworthiness Directives; PAN AVION: Applies to Pan Avion Model C-30A Life Rafts Serial Numbers 81 through 716

AD Number
74-22-03
Status
final_rule
Effective Date
Product Category
appliance
Docket
Unknown
FR Citation
This information is not available.

Applicability

TypeManufacturerModelDetails
aircraft Pan Avion Company Life Rafts Airworthiness Directives; PAN AVION: Applies to Pan Avion Model C-30A Life Rafts Serial Numbers 81 through 716

Unsafe Condition

Loss of pressure in the inflation system on the rafts due to issues with the gas regulator assembly, P/N 11402-11, and gas bottle.

AI-generated summary from the source AD text. Verify against the official source before acting.

Required Actions

Perform a pressure check of the gas regulator assembly and gas bottle within 2 months after the effective date. If pressure is below 2750 psig at 70°F (or equivalent), comply with modification in paragraph (c). If pressure exceeds 2750 psig, comply with paragraph (c) within 30 days. Modification must follow Pan Avion Service Department Bulletin No. 26-74 or FAA-approved equivalent.

AI-generated summary from the source AD text. Verify against the official source before acting.

Compliance Time

Within 2 months time in service after the effective date of this AD

AI-generated summary from the source AD text. Verify against the official source before acting.

Affected Aircraft

Pan Avion Model C-30A Life Rafts, Serial Numbers 81 through 716

AI-generated summary from the source AD text. Verify against the official source before acting.

Source: Official FAA Source ↗

Retrieved: Apr 8, 2026

Rights: U.S. Government Public Domain