AD 74-11-05
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Gulfstream Aerospace Corporation | G-1159 | Airworthiness Directives; GRUMMAN AMERICAN AVIATION CORPORATION Model G-1159 |
Unsafe Condition
The fire extinguisher circuits may fail due to insufficient redundancy in the electrical squib circuits, which could prevent activation of the fire extinguishing system during an emergency.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Replace left and right fire extinguisher switches MS24523-21 with MS24524-21 switches, wire switches according to Grumman Gulfstream II Aircraft Service Change 121, and replace pilot's circuit breaker panel nameplate 1159AV2042 with 1159SB20082-11.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
within the next 100 hours time in service after the effective date of this AD
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Grumman American Aviation Corporation Model G-1159, serial numbers 1 through 110 and 775 except 91 and 95
AI-generated summary from the source AD text. Verify against the official source before acting.
Source: Official FAA Source ↗
Retrieved: Apr 8, 2026
Rights: U.S. Government Public Domain