AD 73-24-02
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Eagle Balloons Corp. | 30-AL | Airworthiness Directives; Semco Model 30-AL, TC-4A, and "Model T," Balloons |
| aircraft | Eagle Balloons Corp. | T | Airworthiness Directives; Semco Model 30-AL, TC-4A, and "Model T," Balloons |
| aircraft | Eagle Balloons Corp. | TC-4A | Airworthiness Directives; Semco Model 30-AL, TC-4A, and "Model T," Balloons |
Unsafe Condition
Inadvertent fuel leakage due to improper connection of the vertical fuel hose coupler assembly (Amflo quick change couplers and plugs) on Semco Model 30-AL, TC-4A, and Model T balloons.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Remove Amflo female coupler C-2 and male plug CP-1, install Amflo male plug CP-2 or female coupler C-1, or alternatively remove components and install AN 901-2 coupling and AN 911-2 nipple with approved parts on the vertical fuel hose and fuel tank connections.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
within the next 25 hours time in service after the effective date of this AD
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Semco Model 30-AL (serials SEM C1, SEM C2, SEM 11-SEM 118), TC-4A (serials SEM 81-SEM 118), and Model T (serials SEM 28, SEM 60-SEM 78 inclusive except SEM 63, SEM 74-SEM 75) balloons.
AI-generated summary from the source AD text. Verify against the official source before acting.
Source: Official FAA Source ↗
Retrieved: Apr 8, 2026
Rights: U.S. Government Public Domain