AD 73-24-01
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Commander Aircraft Corporation | 112 | Airworthiness Directives; Rockwell International Rockwell Commander Model 112 Airplanes |
Unsafe Condition
Failure of the aileron hinges and/or the elevator trim tab hinges due to the use of formed hinge halves made by rolling the edge of a 0.040 inches thick flat sheet, which are less durable than the extruded type 0.060 inches thick hinges.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Inspect all hinge halves of both ailerons and both elevator trim tabs from the underside of the aircraft. Replace formed hinge halves with Rockwell Commander Part No. 42251-1 (aileron hinges) or Part No. 44020-5 (elevator trim tab hinges) before further flight if cracks are present. If no cracks are evident, the airplane may be flown to a base for replacement under FAR 21.197.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
before further flight unless already accomplished
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Rockwell International Rockwell Commander Model 112 airplanes, Serial Numbers 3 through 120, certificated in all categories.
AI-generated summary from the source AD text. Verify against the official source before acting.
Source: Official FAA Source ↗
Retrieved: Apr 8, 2026
Rights: U.S. Government Public Domain