AD 71-20-03
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Sud Aviation | Caravelle SE 210 Model VIR | Airworthiness Directives; SUD AVIATION Model SE.210, MK VI-R Airplanes |
Unsafe Condition
Failure of the relay in the elevator servodyne circuit could result in an inoperative jamming warning system for the elevator servodyne.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Install a holding relay in the elevator servodyne jamming warning circuit in accordance with Sud Service-Caravelle Bulletin No. 27-218 at Revision 4, dated March 27, 1970, or an FAA-approved equivalent.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
within the next 500 hours' time in service after the effective date of this AD
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Sud Aviation Model SE.210, MK VI-R 'Caravelle' airplanes
AI-generated summary from the source AD text. Verify against the official source before acting.
Source: Official FAA Source ↗
Retrieved: Apr 8, 2026
Rights: U.S. Government Public Domain