Unsafe Condition
Hazardous drift in the bus-bar undervoltage sensing unit setting
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Replace transistor T.1 in the Rotax Voltage Sensing Unit Type U.3619 with a new transistor in accordance with Rotax Service Bulletin No. 24-368 dated 4 May 1970, or later ARB-approved issue or FAA approved equivalent. Incorporate Rotax Modification SP7174.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
within the next 1000 hours' time in service after the effective date of this AD or upon installation of the bus-bar undervoltage warning light in accordance with AD 70-02-04, whichever occurs later
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Vickers-Armstrongs (Aircraft Limited) Viscount 744, Viscount 745D, and Viscount 810 series airplanes
AI-generated summary from the source AD text. Verify against the official source before acting.