AD 70-15-09

final rule
Data completeness: 70%

Airworthiness Directives; BRITISH AIRCRAFT CORPORATION Model BAC 1-11 200 and 400 Series Airplanes

AD Number
70-15-09
Status
final_rule
Effective Date
Product Category
aircraft
Docket
Unknown
FR Citation
This information is not available.

Applicability

TypeManufacturerModelDetails
aircraft Airbus SAS BAC 1-11 200 Series Airworthiness Directives; BRITISH AIRCRAFT CORPORATION Model BAC 1-11 200 and 400 Series Airplanes
aircraft Airbus SAS BAC 1-11 400 Series Airworthiness Directives; BRITISH AIRCRAFT CORPORATION Model BAC 1-11 200 and 400 Series Airplanes

Unsafe Condition

The existing 200 ampere fuse in the APU starter motor circuit may fail due to overload, and airplanes without BAC 1-11 Modification PM2518 may have inadequate APU starting system protection.

AI-generated summary from the source AD text. Verify against the official source before acting.

Required Actions

Replace the 200 ampere fuse with a 150 ampere fuse per Service Bulletin 49-PM4480. For airplanes without PM2518, install a second power relay per SB 49-PM2429 Rev 4 and a separate APU start control per SB 49-PM2891 Rev 5. Airplanes with PM2518 must complete these modifications within 1500 hours' time in service.

AI-generated summary from the source AD text. Verify against the official source before acting.

Compliance Time

within the next 750 hours' time in service after the effective date of this AD

AI-generated summary from the source AD text. Verify against the official source before acting.

Affected Aircraft

BRITISH AIRCRAFT CORPORATION Model BAC 1-11 200 and 400 Series airplanes

AI-generated summary from the source AD text. Verify against the official source before acting.

Source: Official FAA Source ↗

Retrieved: Apr 8, 2026

Rights: U.S. Government Public Domain