AD 70-06-07

final rule

Airworthiness Directives; AVIONS MARCEL DASSAULT/SUD-AVIATION Model Fan Jet Falcon Airplanes

AD Number
70-06-07
Status
final_rule
Effective Date
Product Category
aircraft
Docket
Unknown
FR Citation
This information is not available.

Applicability

TypeManufacturerModelDetails
aircraft Dassault Aviation Fan Jet Falcon Airworthiness Directives; AVIONS MARCEL DASSAULT/SUD-AVIATION Model Fan Jet Falcon Airplanes

Unsafe Condition

Fire hazard due to continued operation of the APU oil pump motor after APU shutdown.

AI-generated summary from the source AD text. Verify against the official source before acting.

Required Actions

Replace Equipment Construction Electrique (ECE) relay P/N 1475-7 with ECE contactor P/N 100CC01-A following Microturbo Saphir I Service Bulletin 49.10.39 or Saphir II Service Bulletin 49.11.08, Revision No. 1, or later SGAC/FAA-approved equivalents.

AI-generated summary from the source AD text. Verify against the official source before acting.

Compliance Time

within the next 75 hours of APU operation

AI-generated summary from the source AD text. Verify against the official source before acting.

Affected Aircraft

AVIONS MARCEL DASSAULT/SUD-AVIATION Model Fan Jet Falcon airplanes with Microturbo Saphir I and II APU's installed.

AI-generated summary from the source AD text. Verify against the official source before acting.

Federal Register Abstract

Relay for APU Oil Pump

Applicability Source Text

Show captured applicability text from the source AD
AD Final Rules - DRS_70-06-07.html
Copy URL
Print/Save as PDF
Document Versions
 Feedback
Details
AD Number:
70-06-07
Document Type:
AD Final Rules
Docket Number:
Unknown
Subject Heading:
Airworthiness Directives; AVIONS MARCEL DASSAULT/SUD-AVIATION Model Fan Jet Falcon Airplanes
Subject:
Relay for APU Oil Pump
Status:
Current
Citation:
This information is not available.
Citation Publish Date:
Effective Date:
04/18/1970
Make:
Dassault Aviation
Model:
Fan Jet Falcon
Product Type:
Aircraft
Product Subtype:
Large Airplane
Affected AD:
Superseded AD:
Affected By:
Superseded By:
Service/Office:
Office of Primary Responsibility:
CFR Part Reference:
Part 39
Comments:
AIRWORTHINESS DIRECTIVES FINAL RULES: 70-06-07
CITATION:   This information is not available.

PAGE NUMBER:  

DOCKET NUMBER:   Unknown

AMENDMENT:   39-958

AD NUMBER:   70-06-07

SUBJECT HEADING:   Airworthiness Directives; AVIONS MARCEL DASSAULT/SUD-AVIATION Model Fan Jet Falcon Airplanes

ACTION:  

SUMMARY:  

DATES:   Effective April 18, 1970.

ADDRESSES:  

FOR FURTHER INFORMATION CONTACT:  

SUPPLEMENTARY INFORMATION:  

REGULATORY TEXT:  
70-06-07 AVIONS MARCEL DASSAULT/SUD-AVIATION: Amdt. 39-958. Applies to all series Fan Jet Falcon airplanes with Microturbo Saphir I and II APU's installed.

Compliance is required within the next 75 hours of APU operation, unless already accomplished.

To prevent a fire hazard due to continued operation of the APU oil pump motor after APU shutdown, replace Equipment Construction Electrique (ECE) relay P/N 1475-7 with ECE contactor P/N 100CC01-A in accordance with Microturbo Saphir I Service Bulletin 49.10.39, dated September 30, 1969; or Microturbo Saphir II Service Bulletin 49.11.08, Revision No. 1, dated September 30, 1969, as applicable, or later SGAC-approved issues, or FAA-approved equivalents.

This amendment becomes effective April 18, 1970.

FOOTER:

Document Text

Show stored source text (verify against official source)
AD Final Rules - DRS_70-06-07.html
Copy URL
Print/Save as PDF
Document Versions
 Feedback
Details
AD Number:
70-06-07
Document Type:
AD Final Rules
Docket Number:
Unknown
Subject Heading:
Airworthiness Directives; AVIONS MARCEL DASSAULT/SUD-AVIATION Model Fan Jet Falcon Airplanes
Subject:
Relay for APU Oil Pump
Status:
Current
Citation:
This information is not available.
Citation Publish Date:
Effective Date:
04/18/1970
Make:
Dassault Aviation
Model:
Fan Jet Falcon
Product Type:
Aircraft
Product Subtype:
Large Airplane
Affected AD:
Superseded AD:
Affected By:
Superseded By:
Service/Office:
Office of Primary Responsibility:
CFR Part Reference:
Part 39
Comments:
AIRWORTHINESS DIRECTIVES FINAL RULES: 70-06-07
CITATION:   This information is not available.

PAGE NUMBER:  

DOCKET NUMBER:   Unknown

AMENDMENT:   39-958

AD NUMBER:   70-06-07

SUBJECT HEADING:   Airworthiness Directives; AVIONS MARCEL DASSAULT/SUD-AVIATION Model Fan Jet Falcon Airplanes

ACTION:  

SUMMARY:  

DATES:   Effective April 18, 1970.

ADDRESSES:  

FOR FURTHER INFORMATION CONTACT:  

SUPPLEMENTARY INFORMATION:  

REGULATORY TEXT:  
70-06-07 AVIONS MARCEL DASSAULT/SUD-AVIATION: Amdt. 39-958. Applies to all series Fan Jet Falcon airplanes with Microturbo Saphir I and II APU's installed.

Compliance is required within the next 75 hours of APU operation, unless already accomplished.

To prevent a fire hazard due to continued operation of the APU oil pump motor after APU shutdown, replace Equipment Construction Electrique (ECE) relay P/N 1475-7 with ECE contactor P/N 100CC01-A in accordance with Microturbo Saphir I Service Bulletin 49.10.39, dated September 30, 1969; or Microturbo Saphir II Service Bulletin 49.11.08, Revision No. 1, dated September 30, 1969, as applicable, or later SGAC-approved issues, or FAA-approved equivalents.

This amendment becomes effective April 18, 1970.