Unsafe Condition

Fire hazard due to continued operation of the APU oil pump motor after APU shutdown.

AI-generated summary from the source AD text. Verify against the official source before acting.

Required Actions

Replace Equipment Construction Electrique (ECE) relay P/N 1475-7 with ECE contactor P/N 100CC01-A following Microturbo Saphir I Service Bulletin 49.10.39 or Saphir II Service Bulletin 49.11.08, Revision No. 1, or later SGAC/FAA-approved equivalents.

AI-generated summary from the source AD text. Verify against the official source before acting.

Compliance Time

within the next 75 hours of APU operation

AI-generated summary from the source AD text. Verify against the official source before acting.

Affected Aircraft

AVIONS MARCEL DASSAULT/SUD-AVIATION Model Fan Jet Falcon airplanes with Microturbo Saphir I and II APU's installed.