AD 67-02-05

final rule
Data completeness: 70%

Airworthiness Directives; VICKERS Models 744 and 745D Airplanes

AD Number
67-02-05
Status
final_rule
Effective Date
Product Category
aircraft
Docket
Unknown
FR Citation
This information is not available.

Applicability

TypeManufacturerModelDetails
aircraft Vickers-Armstrongs (Aircraft Limited) Viscount 744 Airworthiness Directives; VICKERS Models 744 and 745D Airplanes
aircraft Vickers-Armstrongs (Aircraft Limited) Viscount 745D Airworthiness Directives; VICKERS Models 744 and 745D Airplanes

Unsafe Condition

Failure of the flying control rod guide beam at Fuselage Station 399.25 due to cracks at the top and bottom extremities of the vertical slot for the trim chains.

AI-generated summary from the source AD text. Verify against the official source before acting.

Required Actions

Within 25 landings after the effective date, inspect the control rod guide beam for cracks. Repair cracked beams before further flight per BAC PTL 261 or equivalent, and modify beams per BAC Modification D.3179 within 1500 landings. Repeat inspections at intervals not exceeding 250 landings until modified or repaired.

AI-generated summary from the source AD text. Verify against the official source before acting.

Compliance Time

Within the next 25 landings after the effective date of this AD, unless already accomplished within the last 225 landings, and thereafter at intervals not to exceed 250 landings from the last inspection until modified or repaired.

AI-generated summary from the source AD text. Verify against the official source before acting.

Affected Aircraft

Vickers-Armstrongs (Aircraft Limited) Viscount 744 and Viscount 745D airplanes.

AI-generated summary from the source AD text. Verify against the official source before acting.