AD 62-13-01
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Andrea Radio Corporation | Intercommunication Sets | Airworthiness Directives; Andrea Radio Corporation: Applies to All Aircraft Equipped With Intercommunication Sets Models AN/AIC-10A and AN/AIC-18(A-81) |
Unsafe Condition
The adjustable attenuation range exceeding 10 decibels in Intercommunication Sets Models AN/AIC-10A and AN/AIC-18(A-81) could cause range problems when the master level control is not set to full 'ON'.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Modify Model AN/AIC-18(A-81) per Field Modification C41-5115 and Model AN/AIC-10A per C41-5116 to limit attenuation to 10 decibels. Install a placard requiring the master level control on the isolation amplifier be full 'ON' during range problem work. Add 'MOD' marking near the TSO-C50 label after modification.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Within the next 200 hours' time in service after June 1, 1962 for modifications and within 10 hours' time in service for the interim placard installation.
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
All aircraft equipped with Intercommunication Sets Models AN/AIC-10A and AN/AIC-18(A-81), except those with Control Panel Serial Number 332 and subsequent.