AD 62-11-03

final rule

Airworthiness Directives; GRAVINER: Applies to Aircraft Equipped With Automatic Fire Extinguisher Cartridge Mark 2, A-716, A-717, A-718, A-719 and Fenwal P/N 690202-3, A-716, A-717, A-718, A-719

AD Number
62-11-03
Status
final_rule
Effective Date
Product Category
appliance
Docket
Unknown
FR Citation
This information is not available.
Technical illustration of an aircraft electrical generator and wiring assembly
Problem area Electrical system

Applicability

TypeManufacturerModelDetails
aircraft Graviner Fire Extinguishers Airworthiness Directives; GRAVINER: Applies to Aircraft Equipped With Automatic Fire Extinguisher Cartridge Mark 2, A-716, A-717, A-718, A-719 and Fenwal P/N 690202-3, A-716, A-717, A-718, A-719
appliance Graviner Fire Extinguishers Airworthiness Directives; GRAVINER: Applies to Aircraft Equipped With Automatic Fire Extinguisher Cartridge Mark 2, A-716, A-717, A-718, A-719 and Fenwal P/N 690202-3, A-716, A-717, A-718, A-719

Unsafe Condition

The igniter wire in extinguisher cartridges may become corroded in service, leading to resistance readings outside the acceptable 5 to 6 ohms range and potential defective fuse wire.

AI-generated summary from the source AD text. Verify against the official source before acting.

Required Actions

Conduct a continuity inspection using a safety ohmmeter restricting current to 13 milliamperes. Replace defective Mark 2 cartridges with serviceable Mark 2 or improved Mark 3 cartridges. Repeat inspections every 550 hours' time in service or 120 days.

AI-generated summary from the source AD text. Verify against the official source before acting.

Compliance Time

Within the next 275 hours' time in service or the next 60 days, whichever occurs first after the effective date of this AD.

AI-generated summary from the source AD text. Verify against the official source before acting.

Affected Aircraft

Graviner Fire Extinguishers equipped with Automatic Fire Extinguisher Cartridge Mark 2 (A-716, A-717, A-718, A-719) and Fenwal P/N 690202-3 (A-716, A-717, A-718, A-719). Fenwal installations noted are Graviner systems. Does not apply to Mark 3 cartridges.

AI-generated summary from the source AD text. Verify against the official source before acting.

Federal Register Abstract

Fire Extinguisher Cartridge

Applicability Source Text

Show captured applicability text from the source AD
AD Final Rules - DRS_62-11-03.html
Copy URL
Print/Save as PDF
Document Versions
 Feedback
Details
AD Number:
62-11-03
Document Type:
AD Final Rules
Docket Number:
Unknown
Subject Heading:
Airworthiness Directives; GRAVINER: Applies to Aircraft Equipped With Automatic Fire Extinguisher ...Show more
Subject:
Fire Extinguisher Cartridge
Status:
Current
Citation:
This information is not available.
Citation Publish Date:
Effective Date:
05/22/1962
Make:
Graviner
Model:
Fire Extinguishers
Product Type:
Appliance
Product Subtype:
Affected AD:
Superseded AD:
Affected By:
Superseded By:
Service/Office:
Office of Primary Responsibility:
CFR Part Reference:
Part 39
Comments:
AIRWORTHINESS DIRECTIVES FINAL RULES: 62-11-03
CITATION:   This information is not available.

PAGE NUMBER:  

DOCKET NUMBER:   Unknown

AMENDMENT:  

AD NUMBER:   62-11-03

SUBJECT HEADING:   Airworthiness Directives; GRAVINER: Applies to Aircraft Equipped With Automatic Fire Extinguisher Cartridge Mark 2,
A-716, A-717, A-718, A-719 and Fenwal P/N 690202-3, A-716, A-717, A-718, A-719

ACTION:  

SUMMARY:  

DATES:   Effective May 22, 1962.

ADDRESSES:  

FOR FURTHER INFORMATION CONTACT:  

SUPPLEMENTARY INFORMATION:  

REGULATORY TEXT:  
62-11-03 GRAVINER: Amdt. 429 Part 507 Federal Register April 21, 1962. Applies to Aircraft Equipped With Automatic Fire Extinguisher Cartridge Mark 2, A-716, A-717, A-718, A-719 and Fenwal P/N 690202-3, A-716, A-717, A-718, A-719. (The Fenwal Installations Noted Are Graviner Systems. Some Mark 2 Cartridges Modified to Mark 3 Have "-3" Added to The Number on The Flat Plate, i.e., A-716-3, Etc. This AD Does Not Apply to Mark 3 Cartridges.)

Compliance required as indicated.

As a result of instances of the igniter wire in extinguisher cartridges becoming corroded in service, the following shall be accomplished:

(a) Within the next 275 hours' time in service or the next 60 days, whichever occurs first after effective date of this AD, unless already accomplished within the past 275 hours' time in service or the past 60 days conduct a continuity inspection of the cartridge circuits using a safety ohmmeter which restricts the current used to 13 milliamperes. A resistance reading of between 5 and 6 ohms indicates a serviceable fuse wire. A resistance reading not between 5 and 6 ohms indicates a defective fuse wire. Repetitive inspection of all cartridge circuits shall be accomplished within each succeeding 550 hours' time in service or 120 days, whichever occurs first after the last inspection.

(b) Replace defective Mark 2 cartridges with either serviceable Mark 2 cartridges or with Mark 3 cartridges which have an improved fuse wire. If Mark 2 cartridges are installed the repetitive inspection specified in (a) shall be continued. If Mark 3 cartridges are installed the repetitive inspections specified in (a) may be discontinued.

(c) Upon request of the operator, an FAA maintenance inspector, subject to prior approval of the Chief, Engineering and Manufacturing Branch, International Division, may adjust the repetitive inspection intervals specified in this AD to permit compliance of an established inspection period of the operator if the request contains substantiating data to justify the increase for such operator.

(Graviner Technical Notice No. 2 covers this subject.)

This supersedes AD 61-02-01.

This directive effective May 22, 1962.

FOOTER:

Document Text

Show stored source text (verify against official source)
AD Final Rules - DRS_62-11-03.html
Copy URL
Print/Save as PDF
Document Versions
 Feedback
Details
AD Number:
62-11-03
Document Type:
AD Final Rules
Docket Number:
Unknown
Subject Heading:
Airworthiness Directives; GRAVINER: Applies to Aircraft Equipped With Automatic Fire Extinguisher ...Show more
Subject:
Fire Extinguisher Cartridge
Status:
Current
Citation:
This information is not available.
Citation Publish Date:
Effective Date:
05/22/1962
Make:
Graviner
Model:
Fire Extinguishers
Product Type:
Appliance
Product Subtype:
Affected AD:
Superseded AD:
Affected By:
Superseded By:
Service/Office:
Office of Primary Responsibility:
CFR Part Reference:
Part 39
Comments:
AIRWORTHINESS DIRECTIVES FINAL RULES: 62-11-03
CITATION:   This information is not available.

PAGE NUMBER:  

DOCKET NUMBER:   Unknown

AMENDMENT:  

AD NUMBER:   62-11-03

SUBJECT HEADING:   Airworthiness Directives; GRAVINER: Applies to Aircraft Equipped With Automatic Fire Extinguisher Cartridge Mark 2,
A-716, A-717, A-718, A-719 and Fenwal P/N 690202-3, A-716, A-717, A-718, A-719

ACTION:  

SUMMARY:  

DATES:   Effective May 22, 1962.

ADDRESSES:  

FOR FURTHER INFORMATION CONTACT:  

SUPPLEMENTARY INFORMATION:  

REGULATORY TEXT:  
62-11-03 GRAVINER: Amdt. 429 Part 507 Federal Register April 21, 1962. Applies to Aircraft Equipped With Automatic Fire Extinguisher Cartridge Mark 2, A-716, A-717, A-718, A-719 and Fenwal P/N 690202-3, A-716, A-717, A-718, A-719. (The Fenwal Installations Noted Are Graviner Systems. Some Mark 2 Cartridges Modified to Mark 3 Have "-3" Added to The Number on The Flat Plate, i.e., A-716-3, Etc. This AD Does Not Apply to Mark 3 Cartridges.)

Compliance required as indicated.

As a result of instances of the igniter wire in extinguisher cartridges becoming corroded in service, the following shall be accomplished:

(a) Within the next 275 hours' time in service or the next 60 days, whichever occurs first after effective date of this AD, unless already accomplished within the past 275 hours' time in service or the past 60 days conduct a continuity inspection of the cartridge circuits using a safety ohmmeter which restricts the current used to 13 milliamperes. A resistance reading of between 5 and 6 ohms indicates a serviceable fuse wire. A resistance reading not between 5 and 6 ohms indicates a defective fuse wire. Repetitive inspection of all cartridge circuits shall be accomplished within each succeeding 550 hours' time in service or 120 days, whichever occurs first after the last inspection.

(b) Replace defective Mark 2 cartridges with either serviceable Mark 2 cartridges or with Mark 3 cartridges which have an improved fuse wire. If Mark 2 cartridges are installed the repetitive inspection specified in (a) shall be continued. If Mark 3 cartridges are installed the repetitive inspections specified in (a) may be discontinued.

(c) Upon request of the operator, an FAA maintenance inspector, subject to prior approval of the Chief, Engineering and Manufacturing Branch, International Division, may adjust the repetitive inspection intervals specified in this AD to permit compliance of an established inspection period of the operator if the request contains substantiating data to justify the increase for such operator.

(Graviner Technical Notice No. 2 covers this subject.)

This supersedes AD 61-02-01.

This directive effective May 22, 1962.

FOOTER:

Source: Official FAA Source ↗

Retrieved: Apr 8, 2026

Rights: U.S. Government Public Domain

This site is not affiliated with or endorsed by the FAA. Always verify with official sources.