AD 62-08-06

final rule
Data completeness: 70%

Airworthiness Directives; CANADAIR Model CL-44D4 Aircraft

AD Number
62-08-06
Status
final_rule
Effective Date
Product Category
aircraft
Docket
Unknown
FR Citation
This information is not available.

Applicability

TypeManufacturerModelDetails
aircraft Bombardier Inc. CL-44D4 Airworthiness Directives; CANADAIR Model CL-44D4 Aircraft

Unsafe Condition

Engine breather duct overheat detectors may not operate at the correct temperature setting, increasing the risk of undetected overheating.

AI-generated summary from the source AD text. Verify against the official source before acting.

Required Actions

Replace engine breather duct overheat detectors with new detectors P/N 28-50603-8 set to 165 degrees C ±15 degrees C or recalibrate existing detectors per Canadair or Fenwal instructions and reidentify them as P/N 28-50603-8.

AI-generated summary from the source AD text. Verify against the official source before acting.

Compliance Time

within next 50 hours' time in service after the effective date of this AD

AI-generated summary from the source AD text. Verify against the official source before acting.

Affected Aircraft

Bombardier Inc. Model CL-44D4 aircraft

AI-generated summary from the source AD text. Verify against the official source before acting.

Source: Official FAA Source ↗

Retrieved: Apr 8, 2026

Rights: U.S. Government Public Domain

This site is not affiliated with or endorsed by the FAA. Always verify with official sources.