AD 58-16-01
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Piper Aircraft Inc. | PA-20 | Airworthiness Directives; Piper Model PA-20 and PA-22 Aircraft |
| aircraft | Piper Aircraft Inc. | PA-22 | Airworthiness Directives; Piper Model PA-20 and PA-22 Aircraft |
Unsafe Condition
A short circuit caused by a faulty cigar lighter element could blow the master fuses.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Install a 15-ampere standard fuse, Bussman No. AGC-15 or equivalent, in the wire between the cigar lighter and the ammeter.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
within next 100 hours of operation
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Piper Model PA-20 Serial Numbers 20-1 to 20-1121 and Model PA-22 Serial Numbers 22-1 to 22-6087 with cigar lighters installed.
AI-generated summary from the source AD text. Verify against the official source before acting.
Federal Register Abstract
Cigar Lighter Fuse
Applicability Source Text
Show captured applicability text from the source AD
AD Final Rules - DRS_58-16-01.html Copy URL Print/Save as PDF Document Versions Feedback Details AD Number: 58-16-01 Document Type: AD Final Rules Docket Number: Unknown Subject Heading: Airworthiness Directives; Piper Model PA-20 and PA-22 Aircraft Subject: Cigar Lighter Fuse Status: Current Citation: This information is not available. Citation Publish Date: 09/26/1958 Effective Date: Make: Piper Aircraft Inc. Model: PA-20 | PA-22 Product Type: Aircraft Product Subtype: Small Airplane Affected AD: Superseded AD: Affected By: Superseded By: Service/Office: AIR-700: Compliance & Airworthiness Division Office of Primary Responsibility: AIR-720: Operational Safety Branch CFR Part Reference: Part 39 Comments: unable to find issue date AIRWORTHINESS DIRECTIVES FINAL RULES: 58-16-01 CITATION: This information is not available. PAGE NUMBER: DOCKET NUMBER: Unknown AMENDMENT: AD NUMBER: 58-16-01 SUBJECT HEADING: Airworthiness Directives; Piper Model PA-20 and PA-22 Aircraft ACTION: SUMMARY: DATES: ADDRESSES: FOR FURTHER INFORMATION CONTACT: SUPPLEMENTARY INFORMATION: REGULATORY TEXT: 58-16-01 PIPER: Applies to Model PA-20 Serial Numbers 20-1 to 20-1121 Inclusive, and Model PA-22 Serial Numbers 22-1 to 22-6087 Inclusive, That Have Cigar Lighters Installed. Compliance required within next 100 hours of operation. To preclude the possibility of blowing the master fuses, due to a short circuit caused by a faulty cigar lighter element, install a 15-ampere standard fuse, Bussman No. AGC-15 or equivalent, in the wire between the cigar lighter and the ammeter. (Piper Service Bulletin Number 163A covers the same subject.) FOOTER:
Document Text
Show stored source text (verify against official source)
AD Final Rules - DRS_58-16-01.html Copy URL Print/Save as PDF Document Versions Feedback Details AD Number: 58-16-01 Document Type: AD Final Rules Docket Number: Unknown Subject Heading: Airworthiness Directives; Piper Model PA-20 and PA-22 Aircraft Subject: Cigar Lighter Fuse Status: Current Citation: This information is not available. Citation Publish Date: 09/26/1958 Effective Date: Make: Piper Aircraft Inc. Model: PA-20 | PA-22 Product Type: Aircraft Product Subtype: Small Airplane Affected AD: Superseded AD: Affected By: Superseded By: Service/Office: AIR-700: Compliance & Airworthiness Division Office of Primary Responsibility: AIR-720: Operational Safety Branch CFR Part Reference: Part 39 Comments: unable to find issue date AIRWORTHINESS DIRECTIVES FINAL RULES: 58-16-01 CITATION: This information is not available. PAGE NUMBER: DOCKET NUMBER: Unknown AMENDMENT: AD NUMBER: 58-16-01 SUBJECT HEADING: Airworthiness Directives; Piper Model PA-20 and PA-22 Aircraft ACTION: SUMMARY: DATES: ADDRESSES: FOR FURTHER INFORMATION CONTACT: SUPPLEMENTARY INFORMATION: REGULATORY TEXT: 58-16-01 PIPER: Applies to Model PA-20 Serial Numbers 20-1 to 20-1121 Inclusive, and Model PA-22 Serial Numbers 22-1 to 22-6087 Inclusive, That Have Cigar Lighters Installed. Compliance required within next 100 hours of operation. To preclude the possibility of blowing the master fuses, due to a short circuit caused by a faulty cigar lighter element, install a 15-ampere standard fuse, Bussman No. AGC-15 or equivalent, in the wire between the cigar lighter and the ammeter. (Piper Service Bulletin Number 163A covers the same subject.) FOOTER:
Source: Official FAA Source ↗
Retrieved: Apr 8, 2026
Rights: U.S. Government Public Domain
This site is not affiliated with or endorsed by the FAA. Always verify with official sources.