AD 47-30-07

final rule

Airworthiness Directives; Beech Model AT-11 Aircraft

AD Number
47-30-07
Status
final_rule
Effective Date
Product Category
aircraft
Docket
Unknown
FR Citation
This information is not available.
Technical illustration of an aircraft electrical generator and wiring assembly
Problem area Electrical system

Applicability

TypeManufacturerModelDetails
aircraft Textron Aviation Inc. Army AT-11 Airworthiness Directives; Beech Model AT-11 Aircraft

Unsafe Condition

Failure of the generator circuit protective devices could result in uncontrolled electrical overloads and potential fire hazards.

AI-generated summary from the source AD text. Verify against the official source before acting.

Required Actions

Install a 50-ampere trip-free circuit breaker (Spencer Thermostat Co. PLM-50 or equivalent) between the battery terminal of each generator cutout and its respective ammeter shunt. Ensure the circuit breakers are accessible in flight and labeled appropriately.

AI-generated summary from the source AD text. Verify against the official source before acting.

Compliance Time

prior to certification or, if certificated, on next periodic inspection but not later than October 1, 1947

AI-generated summary from the source AD text. Verify against the official source before acting.

Affected Aircraft

Beech Model AT-11 aircraft not equipped with generator circuit protective devices.

AI-generated summary from the source AD text. Verify against the official source before acting.

Federal Register Abstract

Trip-Free Circuit Breaker

Applicability Source Text

Show captured applicability text from the source AD
AD Final Rules - DRS_47-30-07.html
Copy URL
Print/Save as PDF
Document Versions
 Feedback
Details
AD Number:
47-30-07
Document Type:
AD Final Rules
Docket Number:
Unknown
Subject Heading:
Airworthiness Directives; Beech Model AT-11 Aircraft
Subject:
Trip-Free Circuit Breaker
Status:
Current
Citation:
This information is not available.
Citation Publish Date:
Effective Date:
Make:
Textron Aviation Inc.
Model:
Army AT-11
Product Type:
Aircraft
Product Subtype:
Small Airplane
Affected AD:
Superseded AD:
Affected By:
Superseded By:
Service/Office:
Office of Primary Responsibility:
CFR Part Reference:
Part 39
Comments:
AIRWORTHINESS DIRECTIVES FINAL RULES: 47-30-07
CITATION:   This information is not available.

PAGE NUMBER:  

DOCKET NUMBER:   Unknown

AMENDMENT:  

AD NUMBER:   47-30-07

SUBJECT HEADING:   Airworthiness Directives; Beech Model AT-11 Aircraft

ACTION:  

SUMMARY:  

DATES:  

ADDRESSES:  

FOR FURTHER INFORMATION CONTACT:  

SUPPLEMENTARY INFORMATION:  

REGULATORY TEXT:  
47-30-07 BEECH: (Was Mandatory Note 3 of AD-2-582-2.) Applies Only to AT-11 Aircraft Which Are Not Equipped With Generator Circuit Protective Devices.

To be accomplished prior to certification or, if certificated, on next periodic inspection but not later than October 1, 1947.

In accordance with Figure 1 install a 50-ampere trip-free circuit breaker, Spencer Thermostat Co. PLM-50 or equivalent, between the battery terminal of each generator cutout and its respective ammeter shunt. The circuit breakers should be accessible in flight and labeled respectively: "LEFT GEN. CIRCUIT" and "RIGHT GEN. CIRCUIT."

FOOTER:

Document Text

Show stored source text (verify against official source)
AD Final Rules - DRS_47-30-07.html
Copy URL
Print/Save as PDF
Document Versions
 Feedback
Details
AD Number:
47-30-07
Document Type:
AD Final Rules
Docket Number:
Unknown
Subject Heading:
Airworthiness Directives; Beech Model AT-11 Aircraft
Subject:
Trip-Free Circuit Breaker
Status:
Current
Citation:
This information is not available.
Citation Publish Date:
Effective Date:
Make:
Textron Aviation Inc.
Model:
Army AT-11
Product Type:
Aircraft
Product Subtype:
Small Airplane
Affected AD:
Superseded AD:
Affected By:
Superseded By:
Service/Office:
Office of Primary Responsibility:
CFR Part Reference:
Part 39
Comments:
AIRWORTHINESS DIRECTIVES FINAL RULES: 47-30-07
CITATION:   This information is not available.

PAGE NUMBER:  

DOCKET NUMBER:   Unknown

AMENDMENT:  

AD NUMBER:   47-30-07

SUBJECT HEADING:   Airworthiness Directives; Beech Model AT-11 Aircraft

ACTION:  

SUMMARY:  

DATES:  

ADDRESSES:  

FOR FURTHER INFORMATION CONTACT:  

SUPPLEMENTARY INFORMATION:  

REGULATORY TEXT:  
47-30-07 BEECH: (Was Mandatory Note 3 of AD-2-582-2.) Applies Only to AT-11 Aircraft Which Are Not Equipped With Generator Circuit Protective Devices.

To be accomplished prior to certification or, if certificated, on next periodic inspection but not later than October 1, 1947.

In accordance with Figure 1 install a 50-ampere trip-free circuit breaker, Spencer Thermostat Co. PLM-50 or equivalent, between the battery terminal of each generator cutout and its respective ammeter shunt. The circuit breakers should be accessible in flight and labeled respectively: "LEFT GEN. CIRCUIT" and "RIGHT GEN. CIRCUIT."

FOOTER: