AD 47-21-08

final rule

Airworthiness Directives; Navion Serial Numbers NAV-4-2 Through 411

AD Number
47-21-08
Status
final_rule
Effective Date
Product Category
aircraft
Docket
Unknown
FR Citation
This information is not available.
Technical illustration of an aircraft electrical generator and wiring assembly
Problem area Electrical system

Applicability

TypeManufacturerModelDetails
aircraft Sierra Hotel Aero, Inc. Navion (Army L-17A) Airworthiness Directives; Navion Serial Numbers NAV-4-2 Through 411

Unsafe Condition

Short circuits between the generator lower terminal and the fitting on the hydraulic pump inlet hose have been reported.

AI-generated summary from the source AD text. Verify against the official source before acting.

Required Actions

Install a self-threading insulator No. 145-54053 (or equivalent) on the generator lower terminal stud.

AI-generated summary from the source AD text. Verify against the official source before acting.

Compliance Time

not later than August 1, 1947

AI-generated summary from the source AD text. Verify against the official source before acting.

Affected Aircraft

Sierra Hotel Aero, Inc. Navion (Army L-17A) serial numbers NAV-4-2 Through 411

AI-generated summary from the source AD text. Verify against the official source before acting.

Federal Register Abstract

Generator Terminal Stud Insulator

Applicability Source Text

Show captured applicability text from the source AD
AD Final Rules - DRS_47-21-08.html
Copy URL
Print/Save as PDF
Document Versions
 Feedback
Details
AD Number:
47-21-08
Document Type:
AD Final Rules
Docket Number:
Unknown
Subject Heading:
Airworthiness Directives; Navion Serial Numbers NAV-4-2 Through 411
Subject:
Generator Terminal Stud Insulator
Status:
Current
Citation:
This information is not available.
Citation Publish Date:
Effective Date:
Make:
Sierra Hotel Aero, Inc.
Model:
Navion (Army L-17A)
Product Type:
Aircraft
Product Subtype:
Small Airplane
Affected AD:
Superseded AD:
Affected By:
Superseded By:
Service/Office:
Office of Primary Responsibility:
CFR Part Reference:
Part 39
Comments:
AIRWORTHINESS DIRECTIVES FINAL RULES: 47-21-08
CITATION:   This information is not available.

PAGE NUMBER:  

DOCKET NUMBER:   Unknown

AMENDMENT:  

AD NUMBER:   47-21-08

SUBJECT HEADING:   Airworthiness Directives; Navion Serial Numbers NAV-4-2 Through 411

ACTION:  

SUMMARY:  

DATES:  

ADDRESSES:  

FOR FURTHER INFORMATION CONTACT:  

SUPPLEMENTARY INFORMATION:  

REGULATORY TEXT:   47-21-08 NAVION: (Was Mandatory Note 7 of AD-782-3.) Applies to Serial Numbers NAV-4-2 Through 411.

To be accomplished not later than August 1, 1947.

Short circuits have been reported caused between the generator lower terminal and the fitting on the hydraulic pump inlet hose. To prevent such short circuits, install a self-threading insulator No. 145-54053 (or equivalent) on the generator lower terminal stud.

(NAA Field Service Bulletin No. 18 covers this change.)

FOOTER:

Document Text

Show stored source text (verify against official source)
AD Final Rules - DRS_47-21-08.html
Copy URL
Print/Save as PDF
Document Versions
 Feedback
Details
AD Number:
47-21-08
Document Type:
AD Final Rules
Docket Number:
Unknown
Subject Heading:
Airworthiness Directives; Navion Serial Numbers NAV-4-2 Through 411
Subject:
Generator Terminal Stud Insulator
Status:
Current
Citation:
This information is not available.
Citation Publish Date:
Effective Date:
Make:
Sierra Hotel Aero, Inc.
Model:
Navion (Army L-17A)
Product Type:
Aircraft
Product Subtype:
Small Airplane
Affected AD:
Superseded AD:
Affected By:
Superseded By:
Service/Office:
Office of Primary Responsibility:
CFR Part Reference:
Part 39
Comments:
AIRWORTHINESS DIRECTIVES FINAL RULES: 47-21-08
CITATION:   This information is not available.

PAGE NUMBER:  

DOCKET NUMBER:   Unknown

AMENDMENT:  

AD NUMBER:   47-21-08

SUBJECT HEADING:   Airworthiness Directives; Navion Serial Numbers NAV-4-2 Through 411

ACTION:  

SUMMARY:  

DATES:  

ADDRESSES:  

FOR FURTHER INFORMATION CONTACT:  

SUPPLEMENTARY INFORMATION:  

REGULATORY TEXT:   47-21-08 NAVION: (Was Mandatory Note 7 of AD-782-3.) Applies to Serial Numbers NAV-4-2 Through 411.

To be accomplished not later than August 1, 1947.

Short circuits have been reported caused between the generator lower terminal and the fitting on the hydraulic pump inlet hose. To prevent such short circuits, install a self-threading insulator No. 145-54053 (or equivalent) on the generator lower terminal stud.

(NAA Field Service Bulletin No. 18 covers this change.)

FOOTER:

Source: Official FAA Source ↗

Retrieved: Apr 8, 2026

Rights: U.S. Government Public Domain

This site is not affiliated with or endorsed by the FAA. Always verify with official sources.