AD 47-20-09

final rule

Airworthiness Directives; ERCO Model 415-C, -CD and -D Aircraft

AD Number
47-20-09
Status
final_rule
Effective Date
Product Category
aircraft
Docket
Unknown
FR Citation
This information is not available.
Technical illustration of an aircraft electrical generator and wiring assembly
Problem area Electrical system

Applicability

TypeManufacturerModelDetails
aircraft Univair Aircraft Corporation 415-C Airworthiness Directives; ERCO Model 415-C, -CD and -D Aircraft
aircraft Univair Aircraft Corporation 415-CD Airworthiness Directives; ERCO Model 415-C, -CD and -D Aircraft
aircraft Univair Aircraft Corporation 415-D Airworthiness Directives; ERCO Model 415-C, -CD and -D Aircraft

Unsafe Condition

Failure of the voltage regulator to maintain proper charging rate of the battery, leading to potential battery overcharging or undercharging.

AI-generated summary from the source AD text. Verify against the official source before acting.

Required Actions

Check the voltage regulator operation by observing the ammeter reading after engine start until the battery is charged. Ensure the charging rate is 11-13 amperes for up to 20 minutes post-start, then reduces to 2 amperes or less within 2 hours of operation.

AI-generated summary from the source AD text. Verify against the official source before acting.

Compliance Time

At each 100-hour inspection and immediately after each electrical system malfunction.

AI-generated summary from the source AD text. Verify against the official source before acting.

Affected Aircraft

Univair Aircraft Corporation Model 415-C, 415-CD, and 415-D aircraft.

AI-generated summary from the source AD text. Verify against the official source before acting.

Federal Register Abstract

Voltage regulator check

Applicability Source Text

Show captured applicability text from the source AD
AD Final Rules - DRS_47-20-09.html
Copy URL
Print/Save as PDF
Document Versions
 Feedback
Details
AD Number:
47-20-09
Document Type:
AD Final Rules
Docket Number:
Unknown
Subject Heading:
Airworthiness Directives; ERCO Model 415-C, -CD and -D Aircraft
Subject:
Voltage regulator check
Status:
Current
Citation:
This information is not available.
Citation Publish Date:
Effective Date:
Make:
Univair Aircraft Corporation
Model:
415-C | 415-CD | 415-D
Product Type:
Aircraft
Product Subtype:
Small Airplane
Affected AD:
Superseded AD:
Affected By:
Superseded By:
Service/Office:
Office of Primary Responsibility:
CFR Part Reference:
Part 39
Comments:
AIRWORTHINESS DIRECTIVES FINAL RULES: 47-20-09
CITATION:   This information is not available.

PAGE NUMBER:  

DOCKET NUMBER:   Unknown

AMENDMENT:  

AD NUMBER:   47-20-09

SUBJECT HEADING:   Airworthiness Directives; ERCO Model 415-C, -CD and -D Aircraft

ACTION:  

SUMMARY:  

DATES:  

ADDRESSES:  

FOR FURTHER INFORMATION CONTACT:  

SUPPLEMENTARY INFORMATION:  

REGULATORY TEXT:   47-20-09 ERCO: (Was Service Note 1 of AD-718-6.) Applies to 415-C, -CD and -D Aircraft.
Compliance required at each 100-hour inspection and immediately after each electrical system malfunction.
Check the operation of the voltage regulator by observing the ammeter reading after starting and until the battery becomes charged. A normal operation would indicate a charging rate up to 11-13 amperes for periods of time up to 20 minutes after starting. The charging rate should reduce to 2 amperes or less within 2 hours or operation.
(Ercoupe Service Department Memorandum No. 23 covers this same subject.)

FOOTER:

Document Text

Show stored source text (verify against official source)
AD Final Rules - DRS_47-20-09.html
Copy URL
Print/Save as PDF
Document Versions
 Feedback
Details
AD Number:
47-20-09
Document Type:
AD Final Rules
Docket Number:
Unknown
Subject Heading:
Airworthiness Directives; ERCO Model 415-C, -CD and -D Aircraft
Subject:
Voltage regulator check
Status:
Current
Citation:
This information is not available.
Citation Publish Date:
Effective Date:
Make:
Univair Aircraft Corporation
Model:
415-C | 415-CD | 415-D
Product Type:
Aircraft
Product Subtype:
Small Airplane
Affected AD:
Superseded AD:
Affected By:
Superseded By:
Service/Office:
Office of Primary Responsibility:
CFR Part Reference:
Part 39
Comments:
AIRWORTHINESS DIRECTIVES FINAL RULES: 47-20-09
CITATION:   This information is not available.

PAGE NUMBER:  

DOCKET NUMBER:   Unknown

AMENDMENT:  

AD NUMBER:   47-20-09

SUBJECT HEADING:   Airworthiness Directives; ERCO Model 415-C, -CD and -D Aircraft

ACTION:  

SUMMARY:  

DATES:  

ADDRESSES:  

FOR FURTHER INFORMATION CONTACT:  

SUPPLEMENTARY INFORMATION:  

REGULATORY TEXT:   47-20-09 ERCO: (Was Service Note 1 of AD-718-6.) Applies to 415-C, -CD and -D Aircraft.
Compliance required at each 100-hour inspection and immediately after each electrical system malfunction.
Check the operation of the voltage regulator by observing the ammeter reading after starting and until the battery becomes charged. A normal operation would indicate a charging rate up to 11-13 amperes for periods of time up to 20 minutes after starting. The charging rate should reduce to 2 amperes or less within 2 hours or operation.
(Ercoupe Service Department Memorandum No. 23 covers this same subject.)

FOOTER:

Source: Official FAA Source ↗

Retrieved: Apr 8, 2026

Rights: U.S. Government Public Domain

This site is not affiliated with or endorsed by the FAA. Always verify with official sources.