AD 47-20-09
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Univair Aircraft Corporation | 415-C | Airworthiness Directives; ERCO Model 415-C, -CD and -D Aircraft |
| aircraft | Univair Aircraft Corporation | 415-CD | Airworthiness Directives; ERCO Model 415-C, -CD and -D Aircraft |
| aircraft | Univair Aircraft Corporation | 415-D | Airworthiness Directives; ERCO Model 415-C, -CD and -D Aircraft |
Unsafe Condition
Failure of the voltage regulator to maintain proper charging rate of the battery, leading to potential battery overcharging or undercharging.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Check the voltage regulator operation by observing the ammeter reading after engine start until the battery is charged. Ensure the charging rate is 11-13 amperes for up to 20 minutes post-start, then reduces to 2 amperes or less within 2 hours of operation.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
At each 100-hour inspection and immediately after each electrical system malfunction.
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Univair Aircraft Corporation Model 415-C, 415-CD, and 415-D aircraft.
AI-generated summary from the source AD text. Verify against the official source before acting.