AD 47-10-11

final rule
Data completeness: 60%

LOCKHEED Model 49

AD Number
47-10-11
Status
final_rule
Effective Date
Product Category
aircraft
Docket
Unknown
FR Citation
This information is not available.

Applicability

TypeManufacturerModelDetails
aircraft Lockheed Aircraft Corporation 49-46 LOCKHEED Model 49

Unsafe Condition

The Fenwall Type S-2223 fire detector units may fail to detect fires in fire seals, firewalls, nacelles, and cabin heater compartments.

AI-generated summary from the source AD text. Verify against the official source before acting.

Required Actions

Replace all Fenwall Type S-2223 fire detector units with Type 17343-3-450 units, installing 100 units per Model 49-51 aircraft and 116 units per Model 49-46 aircraft.

AI-generated summary from the source AD text. Verify against the official source before acting.

Compliance Time

not later than 200 hours of operation after March 1, 1947

AI-generated summary from the source AD text. Verify against the official source before acting.

Affected Aircraft

Lockheed Aircraft Corporation Model 49-46 and 49-51 serial numbers up to and including 2088.

AI-generated summary from the source AD text. Verify against the official source before acting.

Source: Official FAA Source ↗

Retrieved: Apr 8, 2026

Rights: U.S. Government Public Domain