AD 2024-18-04

final rule
Data completeness: 80%

Airworthiness Directives; Bombardier, Inc., Airplanes

AD Number
2024-18-04
Status
final_rule
Effective Date
Product Category
aircraft
Docket
Docket No. FAA-2024-0227
FR Citation
89 FR 81333

Applicability

TypeManufacturerModelDetails
aircraft Bombardier Various Airworthiness Directives; Bombardier, Inc., Airplanes

Unsafe Condition

The fan in a transformer rectifier unit (TRU) can become inoperative in a manner that is not detectable by the fan monitoring circuit, leading to higher TRU operating temperatures, which can trigger the activation of the load shed function to reduce the electrical load and temperature in the TRU.

AI-generated summary from the source AD text. Verify against the official source before acting.

Required Actions

Replace the existing TRU Number 2 with a new part number that incorporates a correction to the fan and the monitoring circuit, and prohibit the installation of affected parts.

AI-generated summary from the source AD text. Verify against the official source before acting.

Compliance Time

Before further flight

AI-generated summary from the source AD text. Verify against the official source before acting.

Affected Aircraft

Bombardier, Inc., Model BD-700-2A12 airplanes, with TRU Number 2 part number G02404521-001.

AI-generated summary from the source AD text. Verify against the official source before acting.

Source: Official FAA Source ↗

Retrieved: Apr 4, 2026

Rights: U.S. Government Public Domain