AD 2024-18-04
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Bombardier | Various | Airworthiness Directives; Bombardier, Inc., Airplanes |
Unsafe Condition
The fan in a transformer rectifier unit (TRU) can become inoperative in a manner that is not detectable by the fan monitoring circuit, leading to higher TRU operating temperatures, which can trigger the activation of the load shed function to reduce the electrical load and temperature in the TRU.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Replace the existing TRU Number 2 with a new part number that incorporates a correction to the fan and the monitoring circuit, and prohibit the installation of affected parts.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Before further flight
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Bombardier, Inc., Model BD-700-2A12 airplanes, with TRU Number 2 part number G02404521-001.
AI-generated summary from the source AD text. Verify against the official source before acting.
Source: Official FAA Source ↗
Retrieved: Apr 4, 2026
Rights: U.S. Government Public Domain