AD 2024-12-07
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Boeing | Company | Airworthiness Directives; The Boeing Company Airplanes |
Unsafe Condition
Cracking in the structure in and around the lavatory service panel, caused by high stress concentrations in the access pan, fuselage skin, and stringer 22 (S-22R) attachment, leading to fatigue cracking.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Repetitively inspect the lavatory service panel, access pan, and attaching structure for cracks; reinforce the attaching structure; replace the access pan or repair cracked parts if necessary.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Within 2,000 flight cycles after the initial inspection.
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
The Boeing Company Model 757-200 airplanes modified by particular supplemental type certificates.
AI-generated summary from the source AD text. Verify against the official source before acting.
Source: Official FAA Source ↗
Retrieved: Apr 6, 2026
Rights: U.S. Government Public Domain