AD 2024-06-15

final rule
Data completeness: 70%

Airworthiness Directives; General Electric Company Engines

AD Number
2024-06-15
Status
final_rule
Effective Date
Product Category
aircraft
Docket
Docket No. FAA-2024-0771
FR Citation
89 FR 41304

Applicability

TypeManufacturerModelDetails
engine General Electric Company Airworthiness Directives; General Electric Company Engines

Unsafe Condition

failure of the HPT due to liberation of the interstage HPT rotor seal rim

AI-generated summary from the source AD text. Verify against the official source before acting.

Required Actions

perform an ultrasonic inspection (USI) of the interstage HPT rotor seal in accordance with the Accomplishment Instructions, paragraph 3.B.(2), of GE SB 72-0908, and remove the interstage HPT rotor seal from service if a non-serviceable indication is found

AI-generated summary from the source AD text. Verify against the official source before acting.

Compliance Time

within the compliance times specified, unless already done

AI-generated summary from the source AD text. Verify against the official source before acting.

Affected Aircraft

General Electric Company (GE) Model GE90-110B1 and GE90-115B engines with an installed interstage high-pressure turbine (HPT) rotor seal having a part number and serial number listed in Table 1 or Table 2 of GE GE90-100 Service Bulletin (SB) 72-0908 R00, dated July 7, 2023 (GE SB 72-0908)

AI-generated summary from the source AD text. Verify against the official source before acting.

Source: Official FAA Source ↗

Retrieved: Apr 6, 2026

Rights: U.S. Government Public Domain