AD 2024-03-09
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Airbus | Canada Limited Partnership Model BD-500-1A11 | Airworthiness Directives; Airbus Canada Limited Partnership (Type Certificate Previously Held by C Series Aircraft Limited Partnership (CSALP); Bombardier, Inc.) Airplanes |
| aircraft | Bombardier | Various | Airworthiness Directives; Airbus Canada Limited Partnership (Type Certificate Previously Held by C Series Aircraft Limited Partnership (CSALP); Bombardier, Inc.) Airplanes |
Unsafe Condition
A manufacturing molding issue with an electrical connector that may prevent the connector from self-locking, which could result in loss of emergency lights, possibly resulting in injury to occupants during an evacuation.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Remove the affected connector, install a new connector, and test the emergency power supply units (EPSUs) 3 and 4, as specified in Transport Canada AD CF-2023-08.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Within 50 flight hours
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Airbus Canada Limited Partnership Model BD-500-1A11 airplanes, certificated in any category, as identified in Transport Canada AD CF-2023-08, dated February 13, 2023 (Transport Canada AD CF-2023-08).
AI-generated summary from the source AD text. Verify against the official source before acting.
Source: Official FAA Source ↗