AD 2021-23-19

final rule
Data completeness: 80%

Airworthiness Directives; Pacific Aerospace Limited Airplanes

AD Number
2021-23-19
Status
final_rule
Effective Date
Product Category
aircraft
Docket
Docket No. FAA-2021-0213
FR Citation
86 FR 69165

Applicability

TypeManufacturerModelDetails
aircraft Aviat Various Airworthiness Directives; Pacific Aerospace Limited Airplanes

Unsafe Condition

insufficient separation of ground terminations for individual power sources and static grounds

AI-generated summary from the source AD text. Verify against the official source before acting.

Required Actions

inspect the battery installation in the engine bay to determine if the ground leads connect to a single ground stud, and if so, separate the battery ground lead connections by following the Accomplishment Instructions, steps 4 through 36, of Pacific Aerospace Mandatory Service Bulletin PACSB/XL/104, Issue 1, dated May 2, 2018

AI-generated summary from the source AD text. Verify against the official source before acting.

Compliance Time

Within 12 months after the effective date of this AD

AI-generated summary from the source AD text. Verify against the official source before acting.

Affected Aircraft

Pacific Aerospace Limited Model 750XL airplanes, serial numbers up to and including 222, certificated in any category, with the battery installed within the engine bay at the firewall