Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| engine | Pratt & Whitney | Division | Airworthiness Directives; Pratt & Whitney Division Turbofan Engines |
Unsafe Condition
damaged or failed 3rd stage LPT duct segments on PW engines with the Talon IIB outer combustion chamber assembly configuration installed, resulting in engine surges, in-flight shutdowns, diversions, and air turnbacks.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Removing and replacing certain 3rd stage LPT duct segments at the next HPT overhaul.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Before further flight
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
All Pratt & Whitney Division (PW) PW4164, PW4164-1D, PW4168, PW4168-1D, PW4168A, PW4168A-1D, and PW4170 model turbofan engines with a certain outer combustion chamber assembly and 3rd stage LPT duct segments installed.
AI-generated summary from the source AD text. Verify against the official source before acting.
Source: Official FAA Source ↗
Retrieved: Apr 6, 2026
Rights: U.S. Government Public Domain