AD 2020-19-13

final rule
Data completeness: 80%

Airworthiness Directives; Bombardier, Inc., Airplanes

AD Number
2020-19-13
Status
final_rule
Effective Date
Product Category
aircraft
Docket
Docket No. FAA-2020-0203
FR Citation
85 FR 60887

Applicability

TypeManufacturerModelDetails
aircraft Bombardier Various Airworthiness Directives; Bombardier, Inc., Airplanes

Unsafe Condition

The portable oxygen bottle installation's upper bracket latch assembly may catch on the pressure gauge tube or on the pressure gauge bezel of the portable oxygen bottle, preventing fast and easy access to the portable oxygen bottle in an emergency situation.

AI-generated summary from the source AD text. Verify against the official source before acting.

Required Actions

A check to identify the manufacturer and part number of the portable oxygen bottle installation, and, if necessary, modification of the portable oxygen bottle installation, as specified in the applicable Bombardier service information.

AI-generated summary from the source AD text. Verify against the official source before acting.

Compliance Time

Before further flight

AI-generated summary from the source AD text. Verify against the official source before acting.

Affected Aircraft

Bombardier, Inc., Model CL-600-1A11 (600), CL-600-2A12 (601), and CL-600-2B16 (601-3A, 601-3R, and 604 Variants) airplanes, with specified part numbers of Scott (Avox/Zodiac) 5500 or 5600 series 11 cubic foot portable oxygen bottle(s).

AI-generated summary from the source AD text. Verify against the official source before acting.

Source: Official FAA Source ↗

Retrieved: Apr 4, 2026

Rights: U.S. Government Public Domain