AD 2019-22-13
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Fokker | Services B | Airworthiness Directives; Fokker Services B.V. Airplanes |
| aircraft | Aviat | Various | Airworthiness Directives; Fokker Services B.V. Airplanes |
Unsafe Condition
Insufficient clearance between the waste bin and the fire extinguisher discharge tubes, which could result in failure to discharge the extinguishing agent during a lavatory bin fire, and consequent damage to the airplane and injury to occupants.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
A one-time inspection of the installation of each affected waste bin for interference between the waste bins and the fire extinguisher discharge tubes (the inspection for interference also includes a weight check of the waste bin fire extinguisher and a detailed inspection of the discharge tubes for damage), modification of affected waste bins, and replacement of affected fire extinguishers.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Before further flight
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Fokker Services B.V. Model F28 Mark 0070 and 0100 airplanes, all serial numbers.
AI-generated summary from the source AD text. Verify against the official source before acting.
Source: Official FAA Source ↗
Retrieved: Apr 6, 2026
Rights: U.S. Government Public Domain