AD 2019-14-08
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Airbus | SAS | Airworthiness Directives; Airbus SAS Airplanes |
| aircraft | Aviat | Various | Airworthiness Directives; Airbus SAS Airplanes |
Unsafe Condition
insufficient clearance between wing structures and electrical wiring, which could lead to chafing damage and arcing, possibly resulting in an on-board fire.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Retain the requirements of AD 2016-07-22 and, for certain airplanes, add a requirement to further modify the electrical installations in both wings, as specified in EASA AD 2019-0014.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Within 50 flight hours
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Airbus SAS Model A300 B4-601, B4-603, B4-620, and B4-622 airplanes, Model A300 B4-605R and B4-622R airplanes, Model A300 F4-605R and F4-622R airplanes, Model A300 C4-605R Variant F airplanes, Model A310-203, -204, -221, -222, -304, -322, -324, and -325 airplanes.
AI-generated summary from the source AD text. Verify against the official source before acting.
Source: Official FAA Source ↗
Retrieved: Apr 4, 2026
Rights: U.S. Government Public Domain
This site is not affiliated with or endorsed by the FAA. Always verify with official sources.