AD 2018-14-05
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Bombardier | Various | Airworthiness Directives; Bombardier, Inc., Airplanes |
Unsafe Condition
Reports of fire incidents of the auxiliary power unit (APU) inlet, which caused tail cone damage after an initial failed APU start followed by two or more in-flight APU start attempts.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Modify the APU electronic control unit (ECU) wiring harness, in accordance with the Accomplishment Instructions of Bombardier Service Bulletin 100-49-04, dated March 29, 2017 (for S/N 20003 through 20500 inclusive); or Bombardier Service Bulletin 350-49-001, dated March 29, 2017 (for S/N 20501 through 20696 inclusive).
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Within 30 months after the effective date of this AD
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Bombardier, Inc., Model BD-100-1A10 airplanes, certificated in any category, serial numbers (S/Ns) 20003 through 20500 inclusive and 20501 through 20696 inclusive.
AI-generated summary from the source AD text. Verify against the official source before acting.
Source: Official FAA Source ↗
Retrieved: Apr 4, 2026
Rights: U.S. Government Public Domain