AD 2018-14-04

final rule
Data completeness: 80%

Airworthiness Directives; Airbus Airplanes

AD Number
2018-14-04
Status
final_rule
Effective Date
Product Category
aircraft
Docket
Docket No. FAA-2018-0270
FR Citation
83 FR 31646

Applicability

TypeManufacturerModelDetails
aircraft Airbus A330-200 Freighter Airworthiness Directives; Airbus Airplanes

Unsafe Condition

blocked vent pipes, in combination with a high level sensor failure, could lead to over-pressurization of the trim tank during refueling or aft fuel transfer, and consequent reduced control of the airplane.

AI-generated summary from the source AD text. Verify against the official source before acting.

Required Actions

doing a trim tank overflow functional test, a general visual inspection of the aperture leading to the flame arrestors (NACA duct), a detailed inspection of the flame arrestor, and blockage removal or repair of any discrepant NACA duct.

AI-generated summary from the source AD text. Verify against the official source before acting.

Compliance Time

Before further flight

AI-generated summary from the source AD text. Verify against the official source before acting.

Affected Aircraft

Airbus Model A330-200 Freighter, A330-200, A330-300, A340-200, A340-300, A340-500, and A340-600 series airplanes.

AI-generated summary from the source AD text. Verify against the official source before acting.

Source: Official FAA Source ↗

Retrieved: Apr 4, 2026

Rights: U.S. Government Public Domain