AD 2017-20-07

final rule
Data completeness: 70%

Airworthiness Directives; Bombardier, Inc., Airplanes

AD Number
2017-20-07
Status
final_rule
Effective Date
Product Category
aircraft
Docket
Docket No. FAA-2017-0518
FR Citation
82 FR 45703

Applicability

TypeManufacturerModelDetails
aircraft Bombardier Various Airworthiness Directives; Bombardier, Inc., Airplanes

Unsafe Condition

Failure of the fire control amplifier (FCA), likely caused by an electrical short in a discharged squib for a fire extinguishing bottle.

AI-generated summary from the source AD text. Verify against the official source before acting.

Required Actions

Replace certain 7.5-amp circuit breakers with 1-amp circuit breakers to prevent damage to squib discharge circuits and the inadvertent discharge of fire extinguishing bottles.

AI-generated summary from the source AD text. Verify against the official source before acting.

Compliance Time

Within 50 flight hours after the effective date of this AD.

AI-generated summary from the source AD text. Verify against the official source before acting.

Affected Aircraft

Bombardier, Inc., Model DHC-8-400, -401, and -402 airplanes, certificated in any category, serial numbers 4001, and 4003 through 4504 inclusive.

AI-generated summary from the source AD text. Verify against the official source before acting.

Source: Official FAA Source ↗

Retrieved: Apr 6, 2026

Rights: U.S. Government Public Domain

This site is not affiliated with or endorsed by the FAA. Always verify with official sources.