AD 2017-19-11

final rule
Data completeness: 70%

Airworthiness Directives; Bombardier, Inc., Airplanes

AD Number
2017-19-11
Status
final_rule
Effective Date
Product Category
aircraft
Docket
Docket No. FAA-2016-8177
FR Citation
82 FR 43457

Applicability

TypeManufacturerModelDetails
aircraft Bombardier Various Airworthiness Directives; Bombardier, Inc., Airplanes

Unsafe Condition

Dormant failures of the pitch feel (PF) and rudder travel limiter actuator (RTLA) back-up modules in the flight control unit (FCU) may not be detected by the existing maintenance task, potentially leading to the inability to maintain minimum control requirements for PF and RTLA, which could create hazardous flight control inputs during flight.

AI-generated summary from the source AD text. Verify against the official source before acting.

Required Actions

Perform an operational test of the FCU back-up modules and repair if necessary, in accordance with a method approved by the Manager, New York ACO Branch, FAA.

AI-generated summary from the source AD text. Verify against the official source before acting.

Compliance Time

Within 30 days after the effective date of this AD.

AI-generated summary from the source AD text. Verify against the official source before acting.

Affected Aircraft

Bombardier, Inc., Model BD-700-1A10 and BD-700-1A11 airplanes.

AI-generated summary from the source AD text. Verify against the official source before acting.

Source: Official FAA Source ↗

Retrieved: Apr 6, 2026

Rights: U.S. Government Public Domain

This site is not affiliated with or endorsed by the FAA. Always verify with official sources.