AD 2017-17-13
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Bombardier | Various | Airworthiness Directives; Bombardier, Inc., Airplanes |
Unsafe Condition
Low clearance in the aft equipment bay between auxiliary power unit (APU) generator power cables and a hydraulic line, which can cause damage to wire insulation and lead to arcing with the metallic hydraulic return line, potentially causing a fire in the aft equipment bay.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Inspect the APU generator power cables and the adjacent hydraulic line for damage, and repair if necessary. Modify the APU generator power cable installation to provide sufficient clearance between the power cables and the hydraulic return line.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Before further flight
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Bombardier, Inc., Model BD-100-1A10 airplanes.
AI-generated summary from the source AD text. Verify against the official source before acting.
Source: Official FAA Source ↗
Retrieved: Apr 6, 2026
Rights: U.S. Government Public Domain