AD 2017-08-01

final rule
Data completeness: 70%

Airworthiness Directives; Gulfstream Aerospace Corporation Airplanes

AD Number
2017-08-01
Status
final_rule
Effective Date
Product Category
aircraft
Docket
Docket No. FAA-2014-0651
FR Citation
82 FR 17533

Applicability

TypeManufacturerModelDetails
aircraft Gulfstream Aerospace Corporation Airworthiness Directives; Gulfstream Aerospace Corporation Airplanes

Unsafe Condition

Reports of two independent types of failure of the fuel boost pump, including overheat damage on internal components and external housing, and fuel leakage.

AI-generated summary from the source AD text. Verify against the official source before acting.

Required Actions

Inspect to determine if fuel boost pumps having a certain part number are installed. Replace the fuel boost pumps having a certain part number. Revise the airplane maintenance or inspection program to include the fuel leak check inspection of the fuel boost pumps specified in the applicable task.

AI-generated summary from the source AD text. Verify against the official source before acting.

Compliance Time

Within 12 months of the effective date of this AD.

AI-generated summary from the source AD text. Verify against the official source before acting.

Affected Aircraft

Gulfstream Aerospace Corporation Model GV and GV-SP airplanes.

AI-generated summary from the source AD text. Verify against the official source before acting.

Source: Official FAA Source ↗

Retrieved: Apr 6, 2026

Rights: U.S. Government Public Domain