AD 2017-06-10
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Bombardier | Various | Airworthiness Directives; Bombardier, Inc. Airplanes |
Unsafe Condition
Overheating of the negative interlock and ground wires at the Emergency Light System Power Supplies, caused by the wire gauge being incompatible with the current load during operational checks, leading to insulation degradation.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Change the wiring gauge for the affected Emergency Lights Power Supplies wiring from 22 to 20 American wire gauge (AWG) in accordance with Bombardier Service Bulletin 84-33-12, Revision B.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Before further flight
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Bombardier, Inc. Model DHC-8-400 series airplanes, as specified in the referenced service bulletin.
AI-generated summary from the source AD text. Verify against the official source before acting.