AD 2016-12-14
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Embraer | S | Airworthiness Directives; Embraer S.A. Airplanes |
Unsafe Condition
Failure of the low-stage bleed check valve; simultaneous failures of both low-stage bleed check valves could result in a dual engine in-flight shutdown.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Replace the air management system (AMS) controller operation program of the AMS controller processor boards. Replace the current low-stage bleed check valve and associated seals.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Before further flight.
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
All Embraer S.A. Model ERJ 170 airplanes; and all Embraer S.A. Model ERJ 190-100 STD, -100 LR, -100 IGW, -200 STD, -200 LR, and -200 IGW airplanes.
AI-generated summary from the source AD text. Verify against the official source before acting.
Source: Official FAA Source ↗
Retrieved: Apr 4, 2026
Rights: U.S. Government Public Domain