AD 2016-08-14
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Airbus | A330-200 and -300 | Airworthiness Directives; Airbus Airplanes |
Unsafe Condition
In-flight fuel drainage is insufficient on A340-500/-600 airplanes, maintenance lights are not qualified explosion-proof, and hot surfaces may exist on bleed systems during normal/failure operations. These conditions, in combination with flammable fuel vapors, could result in fuel tank explosions and consequent loss of the airplane.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Remove bulb-type maintenance lights; install a drain mast on certain airplanes; install muffs on connecting bleed elements on certain airplanes; replace certain insulation sleeves with new insulation sleeves for specific Model A340-200 and -300 series airplanes.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Within 50 flight hours after the effective date of this AD.
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
All Airbus Model A330-200 and -300 series airplanes, and Model A340-200, -300, -500, and -600 series airplanes.
AI-generated summary from the source AD text. Verify against the official source before acting.
Source: Official FAA Source ↗
Retrieved: Apr 6, 2026
Rights: U.S. Government Public Domain