Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Airbus | A320-214 | Airworthiness Directives; Airbus Airplanes |
Unsafe Condition
Incorrect installation of jiffy joint connectors on cables connected to certain Passenger Service Units (PSUs), which could cause the passenger oxygen container to malfunction if the connector becomes disengaged during flight due to vibration.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Identify affected PSUs and perform a detailed inspection to determine if the jiffy joint connector works properly. Depending on findings, rework or replace the jiffy joint connectors.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Before further flight
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Airbus Model A320-214, -232, and -233 airplanes; and Airbus Model A321-211 and -231 airplanes, with specific serial numbers listed in the AD.
AI-generated summary from the source AD text. Verify against the official source before acting.