AD 2016-07-01
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Sikorsky | Various | Airworthiness Directives; Sikorsky Aircraft Corporation (Sikorsky) Helicopters |
Unsafe Condition
An incorrectly installed clamp that does not provide adequate clearance to prevent chafing between the high voltage electrical lines and the hydraulic hoses.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Within 150 hours time-in-service, reroute the left hand and right hand upper deck wiring system by complying with the Instructions, paragraph B, of Sikorsky Aircraft Corporation Special Service Instructions SSI No. 92-070A, Revision A, dated April 25, 2014.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Within 150 hours time-in-service.
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Model S-92A helicopters, serial number 920006 through 920084, certificated in any category.
AI-generated summary from the source AD text. Verify against the official source before acting.
Source: Official FAA Source ↗
Retrieved: Apr 6, 2026
Rights: U.S. Government Public Domain