AD 2015-25-05
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Bombardier Inc. | CL-600-2A12 (CL-601) | Airworthiness Directives; Bombardier, Inc. Airplanes |
| aircraft | Bombardier Inc. | CL-600-2B16 (CL-601-3A) | Airworthiness Directives; Bombardier, Inc. Airplanes |
| aircraft | Bombardier Inc. | CL-600-2B16 (CL-601-3R) | Airworthiness Directives; Bombardier, Inc. Airplanes |
| aircraft | Bombardier Inc. | CL-600-2B16 (CL-604) | Airworthiness Directives; Bombardier, Inc. Airplanes |
Unsafe Condition
Chafing and subsequent arcing of the integrated drive generator (IDG) power cables due to inadequate clearance caused by broken support brackets of the hydraulic line, potentially leading to an uncontrolled fire in the aft equipment bay.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Inspect the IDG power cables for chafing and the hydraulic line support brackets for cracks or breaks. Repair or replace the IDG power cables if chafing is found, and replace any cracked or broken support brackets.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Before further flight
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Bombardier, Inc. Model CL-600-2A12 (CL-601) and CL-600-2B16 (CL-601-3A, CL-601-3R, and CL-604 Variants) airplanes.
AI-generated summary from the source AD text. Verify against the official source before acting.
Federal Register Abstract
We are adopting a new airworthiness directive (AD) for certain Bombardier, Inc. Model CL-600-2A12 (CL-601) and CL-600-2B16 (CL-601-3A, CL-601-3R, and CL-604 Variants) airplanes. This AD was prompted by a report of an aft equipment bay fire due to chafing and subsequent arcing of the integrated drive generator (IDG) power cables. Additionally, we have received several reports of broken support brackets of the hydraulic line. This AD requires a one-time inspection of the IDG power cables for chafing, and for any cracked or broken support bracket of the hydraulic line; and corrective actions if necessary. We are issuing this AD to detect and correct broken support brackets of the hydraulic lines, which could result in inadequate clearance between the IDG power cables and hydraulic lines and chafing of the IDG power cables, and consequent high energy arcing and an uncontrolled fire in the aft equipment bay.
Applicability Source Text
Show captured applicability text from the source AD
(c) Applicability
This AD applies to Bombardier, Inc. airplanes identified in
paragraphs (c)(1), (c)(2), and (c)(3) of this AD, certificated in
any category.
(1) Model CL-600-2A12 (CL-601) airplanes, serial numbers 3001
through 3066 inclusive.
(2) Model CL-600-2B16 (CL-601-3A, CL-601-3R Variants) airplanes,
serial numbers 5001 through 5194 inclusive.
(3) Model CL-600-2B16 (CL-604 Variant) airplanes, serial numbers
5301 through 5665 inclusive, and 5701 through 5934 inclusive.
Document Text
Show stored source text (verify against official source)
[Federal Register Volume 80, Number 247 (Thursday, December 24, 2015)]
[Rules and Regulations]
[Pages 80236-80239]
From the Federal Register Online via the Government Publishing Office [<a href="http://www.gpo.gov">www.gpo.gov</a>]
[FR Doc No: 2015-31604]
-----------------------------------------------------------------------
DEPARTMENT OF TRANSPORTATION
Federal Aviation Administration
14 CFR Part 39
[Docket No. FAA-2014-0625; Directorate Identifier 2014-NM-044-AD;
Amendment 39-18343; AD 2015-25-05]
RIN 2120-AA64
Airworthiness Directives; Bombardier, Inc. Airplanes
AGENCY: Federal Aviation Administration (FAA), Department of
Transportation (DOT).
ACTION: Final rule.
-----------------------------------------------------------------------
SUMMARY: We are adopting a new airworthiness directive (AD) for certain
[[Page 80237]]
Bombardier, Inc. Model CL-600-2A12 (CL-601) and CL-600-2B16 (CL-601-3A,
CL-601-3R, and CL-604 Variants) airplanes. This AD was prompted by a
report of an aft equipment bay fire due to chafing and subsequent
arcing of the integrated drive generator (IDG) power cables.
Additionally, we have received several reports of broken support
brackets of the hydraulic line. This AD requires a one-time inspection
of the IDG power cables for chafing, and for any cracked or broken
support bracket of the hydraulic line; and corrective actions if
necessary. We are issuing this AD to detect and correct broken support
brackets of the hydraulic lines, which could result in inadequate
clearance between the IDG power cables and hydraulic lines and chafing
of the IDG power cables, and consequent high energy arcing and an
uncontrolled fire in the aft equipment bay.
DATES: This AD becomes effective January 28, 2016.
The Director of the Federal Register approved the incorporation by
reference of certain publications listed in this AD as of January 28,
2016.
ADDRESSES: You may examine the AD docket on the Internet at <a href="http://www.regulations.gov/#!docketDetail">http://www.regulations.gov/#!docketDetail</a>;D=FAA-2014-0625 or in person at the
Docket Management Facility, U.S. Department of Transportation, Docket
Operations, M-30, West Building Ground Floor, Room W12-140, 1200 New
Jersey Avenue SE., Washington, DC.
For service information identified in this AD, contact Bombardier,
Inc., 400 C[ocirc]te Vertu Road West, Dorval, Qu[eacute]bec H4S 1Y9,
Canada; telephone 514-85-5000; fax 514-855-7401; email
<a href="/cdn-cgi/l/email-protection#304458541e53425a705155425f1e525f5d525142545955421e535f5d"><span class="__cf_email__" data-cfemail="6d190509430e1f072d0c081f02430f02000f0c1f0904081f430e0200">[email protected]</span></a>; Internet <a href="http://www.bombardier.com">http://www.bombardier.com</a>. You
may view this referenced service information at the FAA, Transport
Airplane Directorate, 1601 Lind Avenue SW., Renton, WA. For information
on the availability of this material at the FAA, call 425-227-1221. It
is also available on the Internet at <a href="http://www.regulations.gov">http://www.regulations.gov</a> by
searching for and locating Docket No. FAA-2014-0625.
FOR FURTHER INFORMATION CONTACT: Assata Dessaline, Aerospace Engineer,
Avionics and Service Branch, ANE-172, FAA, New York Aircraft
Certification Office, 1600 Stewart Avenue, Suite 410, Westbury, NY
11590; telephone (516) 228-7301; fax (516) 794-5531.
SUPPLEMENTARY INFORMATION:
Discussion
We issued a notice of proposed rulemaking (NPRM) to amend 14 CFR
part 39 by adding an AD that would apply to certain Bombardier, Inc.
Model CL-600-2A12 (CL-601) and CL-600-2B16 (CL-601-3A, CL-601-3R, and
CL-604 Variants) airplanes. The NPRM published in the Federal Register
on September 17, 2014 (79 FR 55673).
Transport Canada Civil Aviation (TCCA), which is the aviation
authority for Canada, has issued Canadian Airworthiness Directive CF-
2014-05, dated January 20, 2014 (referred to after this as the
Mandatory Continuing Airworthiness Information, or ``the MCAI''), to
correct an unsafe condition for the specified products. The MCAI
states:
There has been one reported case on the CL-600-2B19 aeroplane of
an aft equipment bay fire occurring due to arcing of chafed
integrated drive generator (IDG) power cables. Additionally, the
hydraulic line support brackets located at the fuselage station (FS)
672 and FS 682 on a CL-600-2B19 aeroplane could result in inadequate
clearance between the IDG power cables and hydraulic lines,
potentially resulting in chafing of the IDG power cables. Chafed IDG
power cables can generate high energy arcing, which can result in an
uncontrolled fire in the aft equipment bay.
It was found that a similar configuration exists on models CL-
600-2A12 and CL-600-2B16 aeroplanes. Therefore, a similar unsafe
condition exists.
This [Canadian] AD mandates the detailed visual inspection and,
if required, rectification of the IDG power cables and hydraulic
line support bracket.
Required corrective actions include repair or replacement of the
IDG power cable if any chafing is found, and replacement of any cracked
or broken support bracket. You may examine the MCAI in the AD docket on
the Internet at <a href="http://www.regulations.gov/#!documentDetail">http://www.regulations.gov/#!documentDetail</a>;D=FAA-2014-
0625-0003.
Comments
We gave the public the opportunity to participate in developing
this AD. The following presents the comments received on the NPRM (79
FR 55673, September 17, 2014) and the FAA's response to each comment.
Request To Correct Typographical Error
Bombardier asked that one of the service bulletin references
identified in the ``Relevant Service Information'' section of the NPRM
(79 FR 55673, September 17, 2014) be changed to correct a typographical
error. Bombardier Service Bulletin ``604-0625,'' as identified in the
``Relevant Service Information'' section, should be identified as
Bombardier Service Bulletin ``601-0625.''
We agree with the commenter for the reason provided, and we have
changed this reference to correctly specify Bombardier Service Bulletin
601-0625 throughout this final rule.
Request To Clarify Credit Provisions
Bombardier asked that we clarify the language in paragraph (h) of
the proposed AD, ``Credit for Previous Actions.'' Bombardier stated
that the current language may cause some confusion because the content
is not clear.
We acknowledge the commenter's concern, and we provide the
following clarification for the credit language used in paragraph (h)
of this AD. Paragraph (h) of this AD matches the intent of the last two
paragraphs in the ``Corrective Actions'' section of Canadian AD CF-
2014-05, dated January 20, 2014. Both this FAA AD and the Canadian AD
give credit for accomplishing Bombardier Service Bulletins 605-24-007,
604-24-026, and 601-0625, all dated September 18, 2012, but only if
Service Request for Product Support Action (SRPSA) 27512, SRPSA 30806,
SRPSA 32727, SRPSA 32864, or SRPSA 33161 has not been done.
Clarification of Airplane Models
We have included the airplane models identified in the service
information in the ``Related Service Information under 1 CFR part 51''
section, and paragraphs (g)(1), (g)(2), and (g)(3) of this AD (79 FR
55673, September 17, 2014), for clarification.
Conclusion
We reviewed the relevant data, considered the comments received,
and determined that air safety and the public interest require adopting
this AD with the changes described previously and minor editorial
changes. We have determined that these minor changes:
<bullet> Are consistent with the intent that was proposed in the
NPRM (79 FR 55673, September 17, 2014) for correcting the unsafe
condition; and
<bullet> Do not add any additional burden upon the public than was
already proposed in the NPRM (79 FR 55673, September 17, 2014).
We also determined that these changes will not increase the
economic burden on any operator or increase the scope of this AD.
Related Service Information Under 1 CFR Part 51
Bombardier has issued the following service information:
<bullet> Bombardier Service Bulletin 605-24-007, Revision 01, dated
January 13,
[[Page 80238]]
2014 (for Model CL-600-2B16 airplanes (CL-604 Variant));
<bullet> Bombardier Service Bulletin 604-24-026, Revision 01, dated
January 13, 2014 (for Model CL-600-2B16 airplanes (CL-604 Variant));
and
<bullet> Bombardier Service Bulletin 601-0625, Revision 01, dated
January 13, 2014 (for Model CL-600-2A12 (CL-601) and CL-600-2B16
airplanes (CL-601-3A and CL-601-3R Variants)).
This service information describes procedures for a one-time
inspection of the IDG power cables for chafing, and for any cracked or
broken support bracket of the hydraulic line; and corrective actions if
necessary. This service information is reasonably available because the
interested parties have access to it through their normal course of
business or by the means identified in the ADDRESSES section.
Costs of Compliance
We estimate that this AD affects 95 airplanes of U.S. registry.
We also estimate that it takes about 1 work-hour per product to
comply with the basic requirements of this AD. The average labor rate
is $85 per work-hour. Based on these figures, we estimate the cost of
this AD on U.S. operators to be $8,075, or $85 per product.
We have received no definitive data that would enable us to provide
cost estimates for the on-condition repair of chafed power cables or
cracked or broken support brackets, as specified in this AD.
Authority for This Rulemaking
Title 49 of the United States Code specifies the FAA's authority to
issue rules on aviation safety. Subtitle I, section 106, describes the
authority of the FAA Administrator. ``Subtitle VII: Aviation
Programs,'' describes in more detail the scope of the Agency's
authority.
We are issuing this rulemaking under the authority described in
``Subtitle VII, Part A, Subpart III, Section 44701: General
requirements.'' Under that section, Congress charges the FAA with
promoting safe flight of civil aircraft in air commerce by prescribing
regulations for practices, methods, and procedures the Administrator
finds necessary for safety in air commerce. This regulation is within
the scope of that authority because it addresses an unsafe condition
that is likely to exist or develop on products identified in this
rulemaking action.
Regulatory Findings
We determined that this AD will not have federalism implications
under Executive Order 13132. This AD will not have a substantial direct
effect on the States, on the relationship between the national
government and the States, or on the distribution of power and
responsibilities among the various levels of government.
For the reasons discussed above, I certify that this AD:
1. Is not a ``significant regulatory action'' under Executive Order
12866;
2. Is not a ``significant rule'' under the DOT Regulatory Policies
and Procedures (44 FR 11034, February 26, 1979);
3. Will not affect intrastate aviation in Alaska; and
4. Will not have a significant economic impact, positive or
negative, on a substantial number of small entities under the criteria
of the Regulatory Flexibility Act.
Examining the AD Docket
You may examine the AD docket on the Internet at <a href="http://www.regulations.gov/#!docketDetail">http://www.regulations.gov/#!docketDetail</a>;D=FAA-2014-0625; or in person at the
Docket Management Facility between 9 a.m. and 5 p.m., Monday through
Friday, except Federal holidays. The AD docket contains this AD, the
regulatory evaluation, any comments received, and other information.
The street address for the Docket Operations office (telephone 800-647-
5527) is in the ADDRESSES section.
List of Subjects in 14 CFR Part 39
Air transportation, Aircraft, Aviation safety, Incorporation by
reference, Safety.
Adoption of the Amendment
Accordingly, under the authority delegated to me by the
Administrator, the FAA amends 14 CFR part 39 as follows:
PART 39--AIRWORTHINESS DIRECTIVES
0
1. The authority citation for part 39 continues to read as follows:
Authority: 49 U.S.C. 106(g), 40113, 44701.
Sec. 39.13 [Amended]
0
2. The FAA amends Sec. 39.13 by adding the following new airworthiness
directive (AD):
2015-25-05 Bombardier, Inc.: Amendment 39-18343; Docket No. FAA-
2014-0625; Directorate Identifier 2014-NM-044-AD.
(a) Effective Date
This AD becomes effective January 28, 2016.
(b) Affected ADs
None.
(c) Applicability
This AD applies to Bombardier, Inc. airplanes identified in
paragraphs (c)(1), (c)(2), and (c)(3) of this AD, certificated in
any category.
(1) Model CL-600-2A12 (CL-601) airplanes, serial numbers 3001
through 3066 inclusive.
(2) Model CL-600-2B16 (CL-601-3A, CL-601-3R Variants) airplanes,
serial numbers 5001 through 5194 inclusive.
(3) Model CL-600-2B16 (CL-604 Variant) airplanes, serial numbers
5301 through 5665 inclusive, and 5701 through 5934 inclusive.
(d) Subject
Air Transport Association (ATA) of America Code 24, Electrical
Power.
(e) Reason
This AD was prompted by a report of an aft equipment bay fire
due to chafing and subsequent arcing of the integrated drive
generator (IDG) power cables. Additionally, we have received several
reports of broken support brackets of the hydraulic lines. We are
issuing this AD to detect and correct broken support brackets of the
hydraulic lines, which could result in inadequate clearance between
the IDG power cables and hydraulic lines and chafing of the IDG
power cables, and consequent high energy arcing and an uncontrolled
fire in the aft equipment bay.
(f) Compliance
Comply with this AD within the compliance times specified,
unless already done.
(g) One-Time Inspection and Corrective Actions
Within 400 flight hours or 18 months after the effective date of
this AD, whichever occurs first: Perform a one-time detailed
inspection of the IDG power cables for chafing between the cables
and the adjacent hydraulic and pneumatic lines, and for any cracked
or broken support bracket of the hydraulic lines, in accordance with
the Accomplishment Instructions of the applicable service
information identified in paragraphs (g)(1), (g)(2), and (g)(3) of
this AD. If any chafing of the power cables or any cracked or broken
support bracket is found, before further flight, repair or replace,
as applicable, in accordance with the Accomplishment Instructions of
the applicable service information identified in paragraphs (g)(1),
(g)(2), and (g)(3) of this AD.
(1) Bombardier Service Bulletin 605-24-007, Revision 01, dated
January 13, 2014 (for Model CL-600-2B16 airplanes (CL-604 Variant)).
(2) Bombardier Service Bulletin 604-24-026, Revision 01, dated
January 13, 2014 (for Model CL-600-2B16 airplanes (CL-604 Variant)).
(3) Bombardier Service Bulletin 601-0625, Revision 01, dated
January 13, 2014 (for Model Cl-600-2A12 (CL-601) and CL-600-2B16
airplanes (CL-601-3A and CL-601-3R Variants)).
(h) Credit for Previous Actions
This paragraph provides credit for action required by paragraph
(g) of this AD, if the
[[Page 80239]]
conditions specified in both paragraphs (h)(1) and (h)(2) of this AD
are met.
(1) The action was performed before the effective date of this
AD using Bombardier Service Bulletin 605-24-007, Bombardier Service
Bulletin 604-24-026, or Bombardier Service Bulletin 601-0625, all
dated September 18, 2012. This service information is not
incorporated by reference in this AD.
(2) The action specified in Service Request for Product Support
Action (SRPSA) 27512, SRPSA 30806, SRPSA 32727, SRPSA 32864, or
SRPSA 33161 has not been done.
(i) Other FAA AD Provisions
The following provisions also apply to this AD:
(1) Alternative Methods of Compliance (AMOCs): The Manager, New
York Aircraft Certification Office (ACO), ANE-170, FAA, has the
authority to approve AMOCs for this AD, if requested using the
procedures found in 14 CFR 39.19. In accordance with 14 CFR 39.19,
send your request to your principal inspector or local Flight
Standards District Office, as appropriate. If sending information
directly to the New York ACO, send it to ATTN: Program Manager,
Continuing Operational Safety, FAA, New York ACO, 1600 Stewart
Avenue, Suite 410, Westbury, NY 11590; telephone 516-228-7300; fax
516-794-553. Before using any approved AMOC, notify your appropriate
principal inspector, or lacking a principal inspector, the manager
of the local flight standards district office/certificate holding
district office. The AMOC approval letter must specifically
reference this AD.
(2) Contacting the Manufacturer: For any requirement in this AD
to obtain corrective actions from a manufacturer, the action must be
accomplished using a method approved by the Manager, New York ACO,
ANE-170, Engine and Propeller Directorate, FAA; or Transport Canada
Civil Aviation (TCCA); or Bombardier, Inc.'s TCCA Design Approval
Organization (DAO). If approved by the DAO, the approval must
include the DAO-authorized signature.
(j) Related Information
(1) Refer to Mandatory Continuing Airworthiness Information
(MCAI) Canadian Airworthiness Directive CF-2014-05, dated January
20, 2014, for related information. This MCAI may be found in the AD
docket on the Internet at <a href="http://www.regulations.gov/#!documentDetail">http://www.regulations.gov/#!documentDetail</a>;D=FAA-2014-0625-0003.
(2) Service information identified in this AD that is not
incorporated by reference is available at the addresses specified in
paragraphs (k)(3) and (k)(4) of this AD.
(k) Material Incorporated by Reference
(1) The Director of the Federal Register approved the
incorporation by reference (IBR) of the service information listed
in this paragraph under 5 U.S.C. 552(a) and 1 CFR part 51.
(2) You must use this service information as applicable to do
the actions required by this AD, unless this AD specifies otherwise.
(i) Bombardier Service Bulletin 605-24-007, Revision 01, dated
January 13, 2014.
(ii) Bombardier Service Bulletin 604-24-026, Revision 01, dated
January 13, 2014.
(iii) Bombardier Service Bulletin 601-0625, Revision 01, dated
January 13, 2014.
(3) For service information identified in this AD, contact
Bombardier, Inc., 400 C[ocirc]te Vertu Road West, Dorval,
Qu[eacute]bec H4S 1Y9, Canada; telephone 514-855-5000; fax 514 855-
7401; email <a href="/cdn-cgi/l/email-protection#4d392529632e3f270d2c283f22632f22202f2c3f2924283f632e2220"><span class="__cf_email__" data-cfemail="7e0a161a501d0c143e1f1b0c11501c11131c1f0c1a171b0c501d1113">[email protected]</span></a>; Internet <a href="http://www.bombardier.com">http://www.bombardier.com</a>.
(4) You may view this service information at the FAA, Transport
Airplane Directorate, 1601 Lind Avenue SW., Renton, WA. For
information on the availability of this material at the FAA, call
425-227-1221.
(5) You may view this service information that is incorporated
by reference at the National Archives and Records Administration
(NARA). For information on the availability of this material at
NARA, call 202-741-6030, or go to: <a href="http://www.archives.gov/federal-register/cfr/ibr-locations.html">http://www.archives.gov/federal-register/cfr/ibr-locations.html</a>.
Issued in Renton, Washington on December 8, 2015.
Michael Kaszycki,
Acting Manager, Transport Airplane Directorate, Aircraft Certification
Service.
[FR Doc. 2015-31604 Filed 12-23-15; 8:45 am]
BILLING CODE 4910-13-P
Source: Official FAA Source ↗
Retrieved: Apr 6, 2026
Rights: U.S. Government Public Domain
This site is not affiliated with or endorsed by the FAA. Always verify with official sources.