AD 2015-22-09
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Boeing | Company | Airworthiness Directives; The Boeing Company Airplanes |
Unsafe Condition
Missing or misaligned plugs in certain stringers of the lower lobe cargo compartments could cause an increased rate of loss of Halon in the event of a fire, potentially leading to the inability to extinguish a fire and consequent loss of control of the airplane.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Drill a hole and install and bond plugs in certain stringers of the lower lobe cargo compartments. Refer to Boeing Alert Service Bulletin B787-81205-SB530024-00, Issue 002, dated June 5, 2015, for detailed instructions.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Before further flight
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
The Boeing Company Model 787-8 airplanes, as specified in the AD, with certain stringers in the lower lobe cargo compartments.
AI-generated summary from the source AD text. Verify against the official source before acting.
Source: Official FAA Source ↗
Retrieved: Apr 6, 2026
Rights: U.S. Government Public Domain