AD 2015-11-03
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | ATR-GIE | Avions de Transport Régional | Airworthiness Directives; ATR-GIE Avions de Transport Régional Airplanes |
Unsafe Condition
Fuel probe failure due to loss of ground connection on the terminal block, caused by incorrect application of wiring instructions during manufacturing between June 2011 and August 2013.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Identify the part number and serial number of the fuel probes. Replace the fuel probes if necessary.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Before further flight.
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
ATR-GIE Avions de Transport Régional Model ATR42 and ATR72 airplanes with fuel probes manufactured between June 2011 and August 2013.
AI-generated summary from the source AD text. Verify against the official source before acting.
Source: Official FAA Source ↗
Retrieved: Apr 6, 2026
Rights: U.S. Government Public Domain