AD 2014-03-05

final rule
Data completeness: 80%

Airworthiness Directives; Bombardier, Inc. Airplanes

AD Number
2014-03-05
Status
final_rule
Effective Date
Product Category
aircraft
Docket
Docket No. FAA-2013-0705
FR Citation
79 FR 10331

Applicability

TypeManufacturerModelDetails
aircraft Bombardier Various Airworthiness Directives; Bombardier, Inc. Airplanes

Unsafe Condition

The use of the HBMU logic circuit to control the line voltage of the drain mast heaters, which are connected in parallel with the number 2 pitot static (PS) probe heater circuit, may result in a number 2 PS probe heater failure not being detected by the fault monitoring capabilities of the HBMU. This could lead to an unannunciated failure of two PS probe heaters, affecting controllability of the airplane in icing conditions.

AI-generated summary from the source AD text. Verify against the official source before acting.

Required Actions

Modify the air data probes and sensors to correct the fault-monitoring capabilities of the HBMU and eliminate the potential dormant failure of the number 2 PS probe heater.

AI-generated summary from the source AD text. Verify against the official source before acting.

Compliance Time

Before further flight

AI-generated summary from the source AD text. Verify against the official source before acting.

Affected Aircraft

Bombardier, Inc. Model BD-700-1A10 airplanes, certificated in any category, equipped with any electrical wiring heater current/brake temperature monitor unit (HBMU) installed in accordance with any FAA supplemental type certificate specified in table 1 of Bombardier Service Bulletin 700-30-021, Revision 01, dated November 21, 2012.

AI-generated summary from the source AD text. Verify against the official source before acting.

Source: Official FAA Source ↗

Retrieved: Apr 4, 2026

Rights: U.S. Government Public Domain

This site is not affiliated with or endorsed by the FAA. Always verify with official sources.