AD 2014-02-08
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Agusta | Various | Airworthiness Directives; Agusta S.p.A. (Type Certificate Currently Held by AgustaWestland S.p.A.) (Agusta) Helicopters |
Unsafe Condition
Loosening of the tail rotor (T/R) locking nut, part number 109-0130-97, due to missing or damaged lock wires securing the locking nut.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Inspect the lock wires securing the tail rotor locking nut to determine if any are missing or damaged. If one or both lock wires are damaged or missing, remove and reassemble the housing and slider group of the tail rotor rotating controls. If only one wire is installed and not damaged, install a second lock wire.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Within 100 hours time-in-service (TIS) if not accomplished as a result of the inspections.
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Agusta Model A109C, A109E, A109S, A109K2, and AW109SP helicopters, with specific serial number ranges as outlined in the AD.
AI-generated summary from the source AD text. Verify against the official source before acting.
Federal Register Abstract
We are adopting a new airworthiness directive (AD) for certain Agusta Model A109C, A109E, A109S, A109K2, and AW109SP helicopters. This AD requires inspecting the lock wires securing the tail rotor (T/R) duplex bearing locking nut (locking nut) to determine whether any lock wires are missing or damaged. This AD was prompted by reports of loosening T/R locking nuts. The actions of this AD are intended to prevent failure of the T/R and subsequent loss of control of the helicopter.
Document Text
Show stored source text (verify against official source)
[Federal Register Volume 79, Number 21 (Friday, January 31, 2014)]
[Rules and Regulations]
[Pages 5257-5259]
From the Federal Register Online via the Government Publishing Office [<a href="http://www.gpo.gov">www.gpo.gov</a>]
[FR Doc No: 2014-01953]
[[Page 5257]]
-----------------------------------------------------------------------
DEPARTMENT OF TRANSPORTATION
Federal Aviation Administration
14 CFR Part 39
[Docket No. FAA-2013-0478; Directorate Identifier 2012-SW-092-AD;
Amendment 39-17736; AD 2014-02-08]
RIN 2120-AA64
Airworthiness Directives; Agusta S.p.A. (Type Certificate
Currently Held by AgustaWestland S.p.A.) (Agusta) Helicopters
AGENCY: Federal Aviation Administration (FAA), DOT.
ACTION: Final rule.
-----------------------------------------------------------------------
SUMMARY: We are adopting a new airworthiness directive (AD) for certain
Agusta Model A109C, A109E, A109S, A109K2, and AW109SP helicopters. This
AD requires inspecting the lock wires securing the tail rotor (T/R)
duplex bearing locking nut (locking nut) to determine whether any lock
wires are missing or damaged. This AD was prompted by reports of
loosening T/R locking nuts. The actions of this AD are intended to
prevent failure of the T/R and subsequent loss of control of the
helicopter.
DATES: This AD is effective March 7, 2014.
ADDRESSES: For service information identified in this AD, contact
Agusta Westland, Customer Support & Services, Via Per Tornavento 15,
21019 Somma Lombardo (VA) Italy, ATTN: Giovanni Cecchelli; telephone
39-0331-711133; fax 39-0331-711180; or at <a href="http://www.agustawestland.com/technical-bullettins">http://www.agustawestland.com/technical-bullettins</a>. You may review the
referenced service information at the FAA, Office of the Regional
Counsel, Southwest Region, 2601 Meacham Blvd., Room 663, Fort Worth,
Texas 76137.
Examining the AD Docket
You may examine the AD docket on the Internet at <a href="http://www.regulations.gov">http://www.regulations.gov</a> or in person at the Docket Operations Office
between 9 a.m. and 5 p.m., Monday through Friday, except Federal
holidays. The AD docket contains this AD, the European Aviation Safety
Agency (EASA) AD, the economic evaluation, any comments received, and
other information. The street address for the Docket Operations Office
(phone: 800-647-5527) is U.S. Department of Transportation, Docket
Operations Office, M-30, West Building Ground Floor, Room W12-140, 1200
New Jersey Avenue SE., Washington, DC 20590.
FOR FURTHER INFORMATION CONTACT: Robert Grant, Aviation Safety
Engineer, Safety Management Group, FAA, 2601 Meacham Blvd., Fort Worth,
Texas 76137; telephone 817-222-5110; email <a href="/cdn-cgi/l/email-protection#e2908d80879096cc8590838c96a2848383cc858d94"><span class="__cf_email__" data-cfemail="72001d101700065c1500131c06321413135c151d04">[email protected]</span></a>.
SUPPLEMENTARY INFORMATION:
Discussion
On June 5, 2013, at 78 FR 33768, the Federal Register published our
notice of proposed rulemaking (NPRM), which proposed to amend 14 CFR
part 39 to add an AD that would apply to Agusta Model A109C, A109S, and
A109K2 helicopters, all serial numbers; Model A109E helicopters, serial
number (S/N) 11002 through 11807 except S/N 11796; and Model AW109SP
helicopters, S/N 22202 through 22278, except S/N 22239, 22264, 22266,
22272, 22273, 22275, and 22277. The NPRM proposed to require
repetitively inspecting the lock wires that secure the T/R locking nut
to the housing to determine whether both wires are present and not
damaged. If only one wire is installed and it is not damaged, the NPRM
proposed installing a second lock wire. If one or both lock wires are
installed and either one or both are damaged, the NPRM proposed
removing and reassembling the housing and slider group of the T/R
rotating controls. The NPRM further proposed removing and reassembling
the housing and slider group of the T/R rotating controls within 100
hours time-in-service (TIS) if not accomplished as a result of the
inspections. Removing and reassembling the housing and slider group of
the T/R rotating controls, either within 100 hours TIS or because a
lock wire is damaged, was proposed as terminating action for the
repetitive inspections. The proposed requirements were intended to
prevent failure of the T/R and subsequent loss of control of the
helicopter.
The NPRM was prompted by AD No. 2012-0195-E, dated September 24,
2012, and corrected September 25, 2012 (AD 2012-0195-E), issued by
EASA, which is the Technical Agent for the Member States of the
European Union. EASA issued AD 2012-0195-E to correct an unsafe
condition for certain Agusta Model A109E, A109LUH, A109S, AW109SP,
A109C, and A109K2 helicopters. EASA advised that they received reports
of the T/R locking nut, part number (P/N) 109-0130-97, loosening on
A109 helicopters. According to EASA, an investigation revealed that, in
every occurrence, one or both of the lock wires securing the locking
nut were either damaged or absent from the T/R, which could lead to
failure of the T/R function and subsequent loss of control of the
helicopter. AD 2012-0195-E requires repetitively inspecting the lock
wires which secure the T/R locking nut for missing and damaged lock
wires, and removing and reassembling the housing and slider group of
the T/R rotating controls, which is terminating action for the
repetitive inspections.
Comments
After our NPRM (78 FR 33768, June 5, 2013) was published, we
received comments from one commenter.
Request
One commenter requested we include a statement that previous
compliance with the applicable Agusta Bollettino Tecnico (BT) fulfills
the requirements of the AD. We disagree that such a statement is
necessary. Paragraph (d) of the AD states you are responsible for
performing each AD action unless it has already been accomplished. This
would include previous compliance with the portions of the service
information that are consistent with the requirements of the AD.
The commenter also requested that we include a statement that the
removal, disassembly, reassembly, and reinstallation of the T/R housing
and slider group is to be accomplished in accordance with the pertinent
part of the Agusta BT, as this would clarify the scope and detail of
work required. We disagree. First, such a statement is not necessary,
as the Agusta BT does not provide a greater level of scope and detail
of work required. The BT only states that removal, disassembly,
reassembly, and reinstallation is to be accomplished in accordance with
the appropriate maintenance manual. Second, such a statement would not
be appropriate because the Agusta BT is only one method of compliance
for this AD. An operator may comply using other methods as long as all
work is done in a manner acceptable to the FAA.
FAA's Determination
These helicopters have been approved by the aviation authority of
Italy and are approved for operation in the United States. Pursuant to
our bilateral agreement with Italy, EASA, its technical representative,
has notified us of the unsafe condition described in the EASA AD. We
are issuing this AD because we evaluated all information provided by
EASA, reviewed the relevant information, considered the comments
received, and determined the unsafe condition exists and is likely to
exist or develop on other helicopters of these same type designs and
that air
[[Page 5258]]
safety and the public interest require adopting the AD requirements as
proposed, except we are including an additional reference for the
actions constituting terminating action for the AD. This change will
neither increase the economic burden on any operator nor increase the
scope of the AD.
Differences Between This AD and the EASA AD
The EASA AD requires reassembling the housing and slider group
within 100 flight hours or 7 months, while this AD requires this action
within 100 hours TIS.
Related Service Information
Agusta has published BT No. 109-134 for Model A109C helicopters, BT
No. 109EP-121 for Model A109E helicopters, BT No. 109S-48 for Model
A109S helicopters, BT No. 109K-54 for Model A109K2 helicopters, and BT
No. 109SP-051 for Model AW109SP helicopters. All of the BTs are dated
September 21, 2012. The BTs specify procedures for inspecting the lock
wires of the T/R locking nut and for removing and reassembling the
housing and slider group of the T/R rotating controls.
Costs of Compliance
We estimate that this AD affects 146 helicopters of U.S. Registry.
We estimate that operators may incur the following costs in order to
comply with this AD. Based on an average labor rate of $85 per hour,
inspecting the lock wire will require about 0.25 work-hour, for a cost
per helicopter of $22 and a total cost to U.S. operators of $3,212 per
inspection cycle. If necessary, installing a lock wire will require
about 0.25 work-hour and the required parts cost are negligible, for a
cost per helicopter of $22 and a total cost to U.S. operators of
$3,212. Removing and reassembling the housing and slider group of the
T/R rotating controls will require about 8 work-hours, for a cost per
helicopter of $680 and a total cost to U.S. operators of $99,280.
Authority for This Rulemaking
Title 49 of the United States Code specifies the FAA's authority to
issue rules on aviation safety. Subtitle I, section 106, describes the
authority of the FAA Administrator. Subtitle VII: Aviation Programs,
describes in more detail the scope of the Agency's authority.
We are issuing this rulemaking under the authority described in
Subtitle VII, Part A, Subpart III, Section 44701: ``General
requirements.'' Under that section, Congress charges the FAA with
promoting safe flight of civil aircraft in air commerce by prescribing
regulations for practices, methods, and procedures the Administrator
finds necessary for safety in air commerce. This regulation is within
the scope of that authority because it addresses an unsafe condition
that is likely to exist or develop on helicopters identified in this
rulemaking action.
Regulatory Findings
This AD will not have federalism implications under Executive Order
13132. This AD will not have a substantial direct effect on the States,
on the relationship between the national government and the States, or
on the distribution of power and responsibilities among the various
levels of government.
For the reasons discussed above, I certify that this AD:
(1) Is not a ``significant regulatory action'' under Executive
Order 12866;
(2) Is not a ``significant rule'' under DOT Regulatory Policies and
Procedures (44 FR 11034, February 26, 1979);
(3) Will not affect intrastate aviation in Alaska to the extent
that it justifies making a regulatory distinction; and
(4) Will not have a significant economic impact, positive or
negative, on a substantial number of small entities under the criteria
of the Regulatory Flexibility Act.
We prepared an economic evaluation of the estimated costs to comply
with this AD and placed it in the AD docket.
List of Subjects in 14 CFR Part 39
Air transportation, Aircraft, Aviation safety, Incorporation by
reference, Safety.
Adoption of the Amendment
Accordingly, under the authority delegated to me by the
Administrator, the FAA amends 14 CFR part 39 as follows:
PART 39--AIRWORTHINESS DIRECTIVES
0
1. The authority citation for part 39 continues to read as follows:
Authority: 49 U.S.C. 106(g), 40113, 44701.
Sec. 39.13 [Amended]
0
2. The FAA amends Sec. 39.13 by adding the following new airworthiness
directive (AD):
2014-02-08 Agusta S.p.A. Helicopters (Type Certificate currently
held by AgustaWestland S.p.A.) (Agusta): Amendment 39-17736; Docket
No. FAA-2013-0478; Directorate Identifier 2012-SW-092-AD.
(a) Applicability
This AD applies to Agusta Model A109C, A109S, and A109K2
helicopters, all serial numbers; Model A109E helicopters, serial
number (S/N) 11002 through 11807 except S/N 11796; and Model AW109SP
helicopters, S/N 22202 through 22278, except S/N 22239, 22264,
22266, 22272, 22273, 22275, and 22277, certificated in any category.
(b) Unsafe Condition
This AD defines the unsafe condition as a missing or broken lock
wire securing the tail rotor (T/R) duplex bearing locking nut
(locking nut). This condition could result in loosening of the
locking nut, failure of the T/R, and subsequent loss of control of
the helicopter.
(c) Effective Date
This AD becomes effective March 7, 2014.
(d) Compliance
You are responsible for performing each action required by this
AD within the specified compliance time unless it has already been
accomplished prior to that time.
(e) Required Actions
(1) Within 5 hours time-in-service (TIS), inspect each lock wire
securing the T/R locking nut to the housing.
(i) If only one lock wire is installed and it is not damaged,
before further flight, install a second lock wire.
(ii) If one or both lock wires are installed, and either one or
both are damaged, before further flight, remove and reassemble the
housing and slider group of the T/R rotating controls.
(2) Within 25 hours TIS from the inspection required by
paragraph (e)(1) of this AD, and thereafter at intervals not
exceeding 25 hours TIS, inspect the lock wires which secure the T/R
locking nut to the housing. If either lock wire is missing or
damaged, before further flight, remove and reassemble the housing
and slider group of the T/R rotating controls.
(3) Within 100 hours TIS, remove and reassemble the housing and
slider group of the T/R rotating controls.
(4) Removing and reassembling the housing and slider group of
the T/R rotating controls as required by paragraph (e)(1)(ii),
(e)(2), or (e)(3) is terminating action for this AD.
(f) Special Flight Permit
Special flight permits are prohibited.
(g) Alternative Methods of Compliance (AMOCs)
(1) The Manager, Safety Management Group, FAA, may approve AMOCs
for this AD. Send your proposal to: Robert Grant, Aviation Safety
Engineer, Safety Management Group, FAA, 2601 Meacham Blvd., Fort
Worth, Texas 76137; telephone 817-222-5110; email
<a href="/cdn-cgi/l/email-protection#b3c1dcd1d6c1c79dd4c1d2ddc7f3d5d2d29dd4dcc5"><span class="__cf_email__" data-cfemail="3d4f525f584f49135a4f5c53497d5b5c5c135a524b">[email protected]</span></a>.
(2) For operations conducted under a 14 CFR part 119 operating
certificate or under 14 CFR part 91, subpart K, we suggest that you
notify your principal inspector, or lacking a principal inspector,
the manager of the local flight standards district office or
certificate holding district office, before
[[Page 5259]]
operating any aircraft complying with this AD through an AMOC.
(h) Additional Information
(1) Agusta Bollettino Tecnico (BT) No. 109-134 for Model A109C
helicopters, BT No. 109EP-121 for Model A109E helicopters, BT No.
109S-48 for Model A109S helicopters, BT No. 109K-54 for Model A109K2
helicopters, and BT No. 109SP-051 for Model AW109SP helicopters, all
dated September 21, 2012, which are not incorporated by reference,
contain additional information about the subject of this AD. For
service information identified in this AD, contact Agusta Westland,
Customer Support & Services, Via Per Tornavento 15, 21019 Somma
Lombardo (VA) Italy, ATTN: Giovanni Cecchelli; telephone 39-0331-
711133; fax 39 0331 711180; or at <a href="http://www.agustawestland.com/technical-bullettins">http://www.agustawestland.com/technical-bullettins</a>. You may review the referenced service
information at the FAA, Office of the Regional Counsel, Southwest
Region, 2601 Meacham Blvd., Room 663, Fort Worth, Texas 76137.
(2) The subject of this AD is addressed in European Aviation
Safety Agency (EASA) AD No. 2012-0195-E, dated September 24, 2012,
and corrected September 25, 2012. You may view the EASA AD on the
internet in the Docket No. FAA-2013-0478 at <a href="http://www.regulations.gov">http://www.regulations.gov</a>.
(i) Subject
Joint Aircraft Service Component (JASC) Code: 6400: Tail Rotor
System.
Issued in Fort Worth, Texas, on January 16, 2014.
Lance T. Gant,
Acting Directorate Manager, Rotorcraft Directorate, Aircraft
Certification Service.
[FR Doc. 2014-01953 Filed 1-30-14; 8:45 am]
BILLING CODE 4910-13-P
Source: Official FAA Source ↗
Retrieved: Apr 4, 2026
Rights: U.S. Government Public Domain
This site is not affiliated with or endorsed by the FAA. Always verify with official sources.