AD 2013-24-04
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Learjet Inc. | 60 | Airworthiness Directives; Learjet Inc. Airplanes |
Unsafe Condition
Chafing and consequent failure of the fuel crossflow tube due to inadequate clearance between the tube and the flight control cables, which could result in loss of fuel from one fuel tank during normal operating conditions or loss of fuel from both main fuel tanks during fuel cross-feeding operations.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Determine if a certain fuel crossflow tube is installed, perform repetitive measurements of the fuel crossflow tube and surrounding valves and cables, and do corrective actions if necessary. Retain all actions from AD 2003-19-11.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Before further flight
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Learjet Inc. Model 60 airplanes, certificated in any category, serial numbers 60-001 through 60-409 inclusive.
AI-generated summary from the source AD text. Verify against the official source before acting.
Federal Register Abstract
We are superseding Airworthiness Directive (AD) 2003-19-11 for certain Learjet Inc. Model 60 airplanes. AD 2003-19-11 required determining if a certain fuel crossflow tube is installed; and follow- on/corrective actions, as applicable. This new AD requires retaining all actions in AD 2003-19-11, and it also requires determining if a certain fuel crossflow tube is installed, performing repetitive measurements of the fuel crossflow tube and surrounding valves and cables, and doing corrective actions if necessary. In addition, this new AD expands the applicability of AD 2003-19-11. This AD was prompted by a report that airplanes produced since 2003 might also be subject to the unsafe condition; and that the minimum allowable clearance is not established in the airplane maintenance information. We are issuing this AD to prevent chafing and consequent failure of the fuel crossflow tube due to inadequate clearance between the tube and the flight control cables, which could result in loss of fuel from one fuel tank during normal operating conditions or loss of fuel from both main fuel tanks during fuel cross-feeding operations.
Applicability Source Text
Show captured applicability text from the source AD
(c) Applicability
This AD applies to Learjet Inc. Model 60 airplanes, certificated
in any category, serial numbers 60-001 through 60-409 inclusive.
Document Text
Show stored source text (verify against official source)
[Federal Register Volume 79, Number 26 (Friday, February 7, 2014)]
[Rules and Regulations]
[Pages 7374-7377]
From the Federal Register Online via the Government Publishing Office [<a href="http://www.gpo.gov">www.gpo.gov</a>]
[FR Doc No: 2014-02464]
[[Page 7374]]
-----------------------------------------------------------------------
DEPARTMENT OF TRANSPORTATION
Federal Aviation Administration
14 CFR Part 39
[Docket No. FAA-2013-0691; Directorate Identifier 2012-NM-170-AD;
Amendment 39-17678; AD 2013-24-04]
RIN 2120-AA64
Airworthiness Directives; Learjet Inc. Airplanes
AGENCY: Federal Aviation Administration (FAA), DOT.
ACTION: Final rule.
-----------------------------------------------------------------------
SUMMARY: We are superseding Airworthiness Directive (AD) 2003-19-11 for
certain Learjet Inc. Model 60 airplanes. AD 2003-19-11 required
determining if a certain fuel crossflow tube is installed; and follow-
on/corrective actions, as applicable. This new AD requires retaining
all actions in AD 2003-19-11, and it also requires determining if a
certain fuel crossflow tube is installed, performing repetitive
measurements of the fuel crossflow tube and surrounding valves and
cables, and doing corrective actions if necessary. In addition, this
new AD expands the applicability of AD 2003-19-11. This AD was prompted
by a report that airplanes produced since 2003 might also be subject to
the unsafe condition; and that the minimum allowable clearance is not
established in the airplane maintenance information. We are issuing
this AD to prevent chafing and consequent failure of the fuel crossflow
tube due to inadequate clearance between the tube and the flight
control cables, which could result in loss of fuel from one fuel tank
during normal operating conditions or loss of fuel from both main fuel
tanks during fuel cross-feeding operations.
DATES: This AD is effective March 14, 2014.
The Director of the Federal Register approved the incorporation by
reference of certain publications listed in this AD as of November 3,
2003 (68 FR 55812, September 29, 2003).
ADDRESSES: For service information identified in this AD, contact
Learjet, Inc., One Learjet Way, Wichita, KS 67209-2942; telephone 316-
946-2000; fax 316-946-2220; email <a href="/cdn-cgi/l/email-protection#d3b2b0fdbab0a793b2b6a1bcfdb1bcbeb1b2a1b7bab6a1fdb0bcbe"><span class="__cf_email__" data-cfemail="89e8eaa7e0eafdc9e8ecfbe6a7ebe6e4ebe8fbede0ecfba7eae6e4">[email protected]</span></a>; Internet
<a href="http://www.bombardier.com">http://www.bombardier.com</a>. You may view this referenced service
information at the FAA, Transport Airplane Directorate, 1601 Lind
Avenue SW., Renton, WA. For information on the availability of this
material at the FAA, call 425-227-1221.
Examining the AD Docket
You may examine the AD docket on the Internet at <a href="http://www.regulations.gov/#!docketBrowser">http://www.regulations.gov/#!docketBrowser</a>;rpp=25;po=0;D=FAA-2013-0691; or in
person at the Docket Management Facility between 9 a.m. and 5 p.m.,
Monday through Friday, except Federal holidays. The AD docket contains
this AD, the regulatory evaluation, any comments received, and other
information. The address for the Docket Office (phone: 800-647-5527) is
Docket Management Facility, U.S. Department of Transportation, Docket
Operations, M-30, West Building Ground Floor, Room W12-140, 1200 New
Jersey Avenue SE., Washington, DC 20590.
FOR FURTHER INFORMATION CONTACT: Jeff Janusz, Aerospace Engineer,
Propulsion Branch, ACE-116W, FAA, Wichita Aircraft Certification Office
(ACO), 1801 Airport Road, Room 100, Wichita, KS 67209; phone: 316-946-
4148; fax: 316-946-4107; email: <a href="/cdn-cgi/l/email-protection#cda7a8ababe3a7aca3b8beb78dabacace3aaa2bb"><span class="__cf_email__" data-cfemail="eb818e8d8dc5818a859e9891ab8d8a8ac58c849d">[email protected]</span></a>.
SUPPLEMENTARY INFORMATION:
Discussion
We issued a notice of proposed rulemaking (NPRM) to amend 14 CFR
part 39 to supersede AD 2003-19-11, Amendment 39-13314 (68 FR 55812,
September 29, 2003). AD 2003-19-11 applied to certain Learjet Inc.
Model 60 airplanes. The NPRM published in the Federal Register on
August 13, 2013 (78 FR 49232). The NPRM was prompted by a report that
airplanes produced since 2003 might also be subject to the unsafe
condition; and that the minimum allowable clearance is not established
in the airplane maintenance information. The NPRM proposed to continue
to require determining if a certain fuel crossflow tube is installed;
and follow-on/corrective actions, as applicable. The NPRM also proposed
to require determining if a certain fuel crossflow tube is installed,
performing repetitive measurements of the fuel crossflow tube and
surrounding valves and cables, and doing corrective actions if
necessary. In addition, the NPRM proposed to expand the applicability
of AD 2003-19-11. We are issuing this AD to prevent chafing and
consequent failure of the fuel crossflow tube due to inadequate
clearance between the tube and the flight control cables, which could
result in loss of fuel from one fuel tank during normal operating
conditions or loss of fuel from both main fuel tanks during fuel cross-
feeding operations.
Comments
We gave the public the opportunity to participate in developing
this AD. We received no comments on the NPRM (78 FR 49232, August 13,
2013) or on the determination of the cost to the public.
Conclusion
We reviewed the relevant data and determined that air safety and
the public interest require adopting this AD as proposed except for
minor editorial changes. We have determined that these minor changes:
<bullet> Are consistent with the intent that was proposed in the
NPRM (78 FR 49232, August 13, 2013) for correcting the unsafe
condition; and
<bullet> Do not add any additional burden upon the public than was
already proposed in the NPRM (78 FR 49232, August 13, 2013).
Costs of Compliance
We estimate that this AD affects 264 airplanes of U.S. registry.
We estimate the following costs to comply with this AD:
Estimated Costs
----------------------------------------------------------------------------------------------------------------
Cost on
Action Labor cost Parts cost Cost per U.S.
product operators
----------------------------------------------------------------------------------------------------------------
Inspection [retained actions from AD 2003- 2 work-hours x $85 per hour $2 $172 $45,408
19-11, Amendment 39-13314 (68 FR 55812, = $170.
September 29, 2003)].
----------------------------------------------------------------------------------------------------------------
We estimate the following costs to do any necessary replacement
that would be required based on the results of the inspection. We have
no way of determining the number of aircraft that might need this
replacement:
[[Page 7375]]
On-Condition Costs
----------------------------------------------------------------------------------------------------------------
Cost per
Action Labor cost Parts cost product
----------------------------------------------------------------------------------------------------------------
Replacement.................................. 4 work-hours x $85 per hour = $20 $360
$340.
----------------------------------------------------------------------------------------------------------------
Paperwork Reduction Act
A federal agency may not conduct or sponsor, and a person is not
required to respond to, nor shall a person be subject to penalty for
failure to comply with a collection of information subject to the
requirements of the Paperwork Reduction Act unless that collection of
information displays a current valid OMB control number. The control
number for the collection of information required by this AD is 2120-
0056. The paperwork cost associated with this AD has been detailed in
the Costs of Compliance section of this document and includes time for
reviewing instructions, as well as completing and reviewing the
collection of information. Therefore, all reporting associated with
this AD is mandatory. Comments concerning the accuracy of this burden
and suggestions for reducing the burden should be directed to the FAA
at 800 Independence Ave. SW., Washington, DC 20591. ATTN: Information
Collection Clearance Officer, AES-200.
Authority for This Rulemaking
Title 49 of the United States Code specifies the FAA's authority to
issue rules on aviation safety. Subtitle I, Section 106, describes the
authority of the FAA Administrator. Subtitle VII, Aviation Programs,
describes in more detail the scope of the Agency's authority.
We are issuing this rulemaking under the authority described in
Subtitle VII, Part A, Subpart III, Section 44701, ``General
requirements.'' Under that section, Congress charges the FAA with
promoting safe flight of civil aircraft in air commerce by prescribing
regulations for practices, methods, and procedures the Administrator
finds necessary for safety in air commerce. This regulation is within
the scope of that authority because it addresses an unsafe condition
that is likely to exist or develop on products identified in this
rulemaking action.
Regulatory Findings
We have determined that this AD will not have federalism
implications under Executive Order 13132. This AD will not have a
substantial direct effect on the States, on the relationship between
the national government and the States, or on the distribution of power
and responsibilities among the various levels of government.
For the reasons discussed above, I certify that this AD:
(1) Is not a ``significant regulatory action'' under Executive
Order 12866,
(2) Is not a ``significant rule'' under DOT Regulatory Policies and
Procedures (44 FR 11034, February 26, 1979),
(3) Will not affect intrastate aviation in Alaska, and
(4) Will not have a significant economic impact, positive or
negative, on a substantial number of small entities under the criteria
of the Regulatory Flexibility Act.
List of Subjects in 14 CFR Part 39
Air transportation, Aircraft, Aviation safety, Incorporation by
reference, Safety.
Adoption of the Amendment
Accordingly, under the authority delegated to me by the
Administrator, the FAA amends 14 CFR part 39 as follows:
PART 39--AIRWORTHINESS DIRECTIVES
0
1. The authority citation for part 39 continues to read as follows:
Authority: 49 U.S.C. 106(g), 40113, 44701.
Sec. 39.13 [Amended]
0
2. The FAA amends Sec. 39.13 by removing Airworthiness Directive (AD)
2003-19-11, Amendment 39-13314 (68 FR 55812, September 29, 2003), and
adding the following new AD:
2013-24-04 Learjet Inc.: Amendment 39-17678; Docket No. FAA-2013-
0691; Directorate Identifier 2012-NM-170-AD.
(a) Effective Date
This AD is effective March 14, 2014.
(b) Affected ADs
This AD supersedes AD 2003-19-11, Amendment 39-13314 (68 FR
55812, September 29, 2003).
(c) Applicability
This AD applies to Learjet Inc. Model 60 airplanes, certificated
in any category, serial numbers 60-001 through 60-409 inclusive.
(d) Subject
Air Transport Association (ATA) of America Code 28, Fuel.
(e) Unsafe Condition
This AD was prompted by a report that airplanes produced since
2003 might also be subject to the unsafe condition; and that the
minimum allowable clearance is not established in the airplane
maintenance information. We are issuing this AD to prevent chafing
and consequent failure of the fuel crossflow tube due to inadequate
clearance between the tube and the flight control cables, which
could result in loss of fuel from one fuel tank during normal
operating conditions or loss of fuel from both main fuel tanks
during fuel cross-feeding operations.
(f) Compliance
Comply with this AD within the compliance times specified,
unless already done.
(g) Retained Part Identification for Airplanes Having Serial Numbers
60-001 Through 60-145 Inclusive
This paragraph restates the part identification required by
paragraph (a) of AD 2003-19-11, Amendment 39-13314 (68 FR 55812,
September 29, 2003). For airplanes having serial numbers 60-001
through 60-145 inclusive: Within 25 flight hours after November 3,
2003 (the effective date of AD 2003-19-11), inspect the fuel
crossflow tube to determine whether part number (P/N) 6026020-005 is
installed. Instead of inspecting the tube, a review of airplane
maintenance records is acceptable if the part number of the tube can
be positively determined from that review.
(h) Retained Clearance Measurement and Corrective Action for Airplanes
Having Serial Numbers 60-001 Through 60-145 Inclusive, With Revised
Repair Language
This paragraph restates the clearance measurement and corrective
action required by paragraph (b) of AD 2003-19-11, Amendment 39-
13314 (68 FR 55812, September 29, 2003), with revised repair
language. For airplanes having serial numbers 60-001 through 60-145
inclusive: If P/N 6026020-005 is found installed during the review
or inspection required by paragraph (g) of this AD, before further
flight, measure the clearance between the fuel crossflow tube and
the flight control cables to determine if it is at least 0.35 inch,
per paragraph 2.B.(8) of the Accomplishment Instructions of
Bombardier Alert Service Bulletin A60-28-3, Revision 2, dated
October 26, 1998.
(1) If the clearance is 0.35 inch or more, no further action is
required by this paragraph.
(2) If the clearance is less than 0.35 inch, before further
flight, repair in accordance with a method approved by the Manager,
Wichita Aircraft Certification Office (ACO), FAA. For a repair
method to be approved by the Manager, Wichita ACO, as required by
[[Page 7376]]
this paragraph, the Manager's approval letter must specifically
refer to this AD.
Note 1 to paragraphs (h) and (j) of this AD: Bombardier Alert
Service Bulletin A60-28-3, Revision 2, dated October 26, 1998,
Figure 1, Detail D, incorrectly identifies the fuel crossflow tube
to be installed as P/N 6026020-001. The manufacturer is aware of
this error and stated it plans to correct the part number in the
next revision of the service information.
(i) Retained Part Replacement, Measurement, and Repair for Airplanes
Having Serial Numbers 60-001 Through 60-055 Inclusive, With Revised
Repair Language
This paragraph restates the part replacement, clearance
measurement, and corrective action required by paragraph (c) of AD
2003-19-11, Amendment 39-13314 (68 FR 55812, September 29, 2003),
with revised repair language. For airplanes having serial numbers
60-001 through 60-055 inclusive: If P/N 6026020-005 is not found
installed during the review or inspection required by paragraph (g)
of this AD, within 90 days after accomplishing the review or
inspection, replace the existing fuel crossflow tube with a new fuel
crossflow tube having P/N 6026020-005, and measure the clearance
between the newly installed fuel crossflow tube and the flight
control cables, per paragraph 2.A. of the Accomplishment
Instructions of Bombardier Service Bulletin 60-28-4, Revision 2,
dated August 22, 2001.
(1) If the clearance is 0.35 inch or more, no further action is
required by this paragraph.
(2) If the clearance is less than 0.35 inch, before further
flight, repair in accordance with a method approved by the Manager,
Wichita ACO, FAA. For a repair method to be approved by the Manager,
Wichita ACO, as required by this paragraph, the Manager's approval
letter must specifically refer to this AD.
(j) Retained Part Replacement, Measurement, and Repair for Airplanes
Having Serial Numbers 60-056 Through 60-145 Inclusive, With Revised
Repair Language
This paragraph restates the part replacement, clearance
measurement, and corrective action required by paragraph (d) of AD
2003-19-11, Amendment 39-13314 (68 FR 55812, September 29, 2003),
with revised repair language. For airplanes having serial numbers
60-056 through 60-145 inclusive: If P/N 6026020-005 is not found
installed during the review or inspection required by paragraph (g)
of this AD, within 90 days after accomplishing the review or
inspection, replace the existing fuel crossflow tube with a new fuel
crossflow tube having P/N 6026020-005, and measure the clearance
between the newly installed fuel crossflow tube and the flight
control cables to determine if the clearance is at least 0.35 inch,
per paragraph 2.B. of the Accomplishment Instructions of Bombardier
Alert Service Bulletin A60-28-3, Revision 2, dated October 26, 1998.
(1) If the clearance is 0.35 inch or more, no further action is
required by this paragraph.
(2) If the clearance is less than 0.35 inch, before further
flight, repair in accordance with a method approved by the Manager,
Wichita ACO, FAA. For a repair method to be approved by the Manager,
Wichita ACO, as required by this paragraph, the Manager's approval
letter must specifically refer to this AD.
(k) New Part Identification
For airplanes having serial numbers 60-001 through 60-409
inclusive: Within 25 flight hours after the effective date of this
AD, inspect the fuel crossflow tube to determine whether P/N
6026020-005 is installed. In lieu of inspecting the tube, a review
of airplane maintenance records is acceptable if the part number of
the tube can be positively determined from that review.
(l) New Clearance Measurement
If P/N 6026020-005 is found installed during the inspection
required by paragraph (k) of this AD, before further flight, measure
the clearance between the fuel crossflow tube and both elevator
control cables to determine if it is 0.35 inch or more, in
accordance with paragraph 2.A.(9) of the Accomplishment Instructions
of Bombardier Service Bulletin 60-28-4, Revision 2, dated August 22,
2001.
(1) If the clearance is 0.35 inch or more, no further action is
required by this paragraph.
(2) If the clearance is less than 0.35 inch, before further
flight, adjust the fit of the P/N 6026020-005 tube to provide 0.35
inch or more clearance to both elevator control cables, in
accordance with paragraph 2.A.(9) of the Accomplishment Instructions
of Bombardier Service Bulletin 60-28-4, Revision 2, dated August 22,
2001. If the tube shows any indication of chafing from the control
cables, before further flight, replace the fuel crossflow tube with
a new fuel crossflow tube, in accordance with paragraph 2.A.(9) of
the Accomplishment Instructions of Bombardier Service Bulletin 60-
28-4, Revision 2, dated August 22, 2001.
(m) New Repetitive Measurements
For all airplanes: As of the effective date of this AD and after
accomplishing the inspection required by paragraph (g) or (k) of
this AD, as applicable: Before further flight after removal,
replacement, or adjustment of any crossflow tube, fuel crossflow
drain valve, fuel crossflow valve or related plumbing and fittings,
and elevator control cable, measure the clearance between the fuel
crossflow tube and the flight control cables, in accordance with
paragraph 2.A.(9) of the Accomplishment Instructions of Bombardier
Service Bulletin 60-28-4, Revision 2, dated August 22, 2001.
(1) If the clearance is 0.35 inch or more, no further action is
required by this paragraph.
(2) If the clearance is less than 0.35 inch, before further
flight, adjust the fit of the P/N 6026020-005 tube to provide 0.35
inch or more clearance to both elevator control cables, in
accordance with paragraph 2.A.(9) of the Accomplishment Instructions
of Bombardier Service Bulletin 60-28-4, Revision 2, dated August 22,
2001.
(n) Reporting Requirement
Submit a report of the findings of the initial measurement
required by paragraph (l) of this AD to the Wichita Manufacturing
Inspection District Office, 2204 South Tyler Road, Wichita, KS
67209-3001, at the applicable time specified in paragraph (n)(1) or
(n)(2) of this AD. The report must include the airplane
registration, serial number, the total time in service, and the
measured clearance found between the fuel crossflow tube and the
elevator control cables after the initial inspection.
(1) If the inspection was done on or after the effective date of
this AD: Submit the report within 30 days after the inspection.
(2) If the inspection was done before the effective date of this
AD: Submit the report within 30 days after the effective date of
this AD.
(o) Part Installation Prohibition
As of the effective date of AD, only fuel crossflow tubes having
P/N 6026020-005 may be installed on any airplane.
(p) Paperwork Reduction Act Burden Statement
A federal agency may not conduct or sponsor, and a person is not
required to respond to, nor shall a person be subject to a penalty
for failure to comply with a collection of information subject to
the requirements of the Paperwork Reduction Act unless that
collection of information displays a current valid OMB Control
Number. The OMB Control Number for this information collection is
2120-0056. Public reporting for this collection of information is
estimated to be approximately 5 minutes per response, including the
time for reviewing instructions, completing and reviewing the
collection of information. All responses to this collection of
information are mandatory. Comments concerning the accuracy of this
burden and suggestions for reducing the burden should be directed to
the FAA at: 800 Independence Ave. SW., Washington, DC 20591, Attn:
Information Collection Clearance Officer, AES-200.
(q) Alternative Methods of Compliance (AMOCs)
(1) The Manager, Wichita ACO, FAA, has the authority to approve
AMOCs for this AD, if requested using the procedures found in 14 CFR
39.19. In accordance with 14 CFR 39.19, send your request to your
principal inspector or local Flight Standards District Office, as
appropriate. If sending information directly to the manager of the
ACO, send it to the attention of the person identified in paragraph
(r) of this AD.
(2) Before using any approved AMOC, notify your appropriate
principal inspector, or lacking a principal inspector, the manager
of the local flight standards district office/certificate holding
district office.
(r) Related Information
For more information about this AD, contact Jeff Janusz,
Aerospace Engineer, Propulsion Branch, ACE-116W, FAA, Wichita ACO,
1801 Airport Road, Room 100, Wichita, KS 67209; phone: 316-946-4148;
fax: 316-946-4107; email: <a href="/cdn-cgi/l/email-protection#1c76797a7a32767d72696f665c7a7d7d327b736a"><span class="__cf_email__" data-cfemail="157f7073733b7f747b60666f557374743b727a63">[email protected]</span></a>.
(s) Material Incorporated by Reference
(1) The Director of the Federal Register approved the
incorporation by reference (IBR) of the service information listed
in this
[[Page 7377]]
paragraph under 5 U.S.C. 552(a) and 1 CFR part 51.
(2) You must use this service information as applicable to do
the actions required by this AD, unless the AD specifies otherwise.
(3) The following service information was approved for IBR on
November 3, 2003 (68 FR 55812, September 29, 2003).
(i) Bombardier Alert Service Bulletin A60-28-3, Revision 2,
dated October 26, 1998.
(ii) Bombardier Service Bulletin 60-28-4, Revision 2, dated
August 22, 2001.
(4) For service information identified in this AD, contact
Learjet, Inc., One Learjet Way, Wichita, KS 67209-2942; telephone
316-946-2000; fax 316-946-2220; email <a href="/cdn-cgi/l/email-protection#1f7e7c31767c6b5f7e7a6d70317d70727d7e6d7b767a6d317c7072"><span class="__cf_email__" data-cfemail="a5c4c68bccc6d1e5c4c0d7ca8bc7cac8c7c4d7c1ccc0d78bc6cac8">[email protected]</span></a>;
Internet <a href="http://www.bombardier.com">http://www.bombardier.com</a>.
(5) You may view this service information at FAA, Transport
Airplane Directorate, 1601 Lind Avenue SW., Renton, WA. For
information on the availability of this material at the FAA, call
425-227-1221.
(6) You may view this service information that is incorporated
by reference at the National Archives and Records Administration
(NARA). For information on the availability of this material at
NARA, call 202-741-6030, or go to: <a href="http://www.archives.gov/federal-register/cfr/ibr-locations.html">http://www.archives.gov/federal-register/cfr/ibr-locations.html</a>.
Issued in Renton, Washington, on December 27, 2013.
Jeffrey E. Duven,
Manager, Transport Airplane Directorate, Aircraft Certification
Service.
[FR Doc. 2014-02464 Filed 2-6-14; 8:45 am]
BILLING CODE 4910-13-P
Source: Official FAA Source ↗
Retrieved: Apr 4, 2026
Rights: U.S. Government Public Domain
This site is not affiliated with or endorsed by the FAA. Always verify with official sources.