AD 2013-20-09
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Bombardier | Various | Airworthiness Directives; Bombardier, Inc. Airplanes |
Unsafe Condition
Chafed power wires due to flexing of the main distribution center (MDC) rack panel, which could cause simultaneous loss of systems such as electrical power, pilot indications, and caution/advisory lighting systems.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Replace the panel assembly of the main distribution center (MDC) rack with a new design that incorporates additional stiffening support structure to prevent flexing of the rack panel.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Within 50 flight hours after the effective date of this AD.
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Bombardier, Inc. Model CL-215-6B11 (CL-415 Variant) airplanes, certificated in any category, serial numbers 2001 through 2076 inclusive.
AI-generated summary from the source AD text. Verify against the official source before acting.
Source: Official FAA Source ↗
Retrieved: Apr 6, 2026
Rights: U.S. Government Public Domain